Key differences

The CyberPower OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 2 kVA more output power capacity than the APC SUA1000RMI1U + WBEXTWAR3YR-SP-03 (3 kVA vs 1 kVA). The CyberPower OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1,760 W more output power than the APC SUA1000RMI1U + WBEXTWAR3YR-SP-03 (2400 W vs 640 W). The APC SUA1000RMI1U + WBEXTWAR3YR-SP-03 has 22 V more output operation voltage (min) than the CyberPower OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (230 V vs 208 V). UPS topology: Line-Interactive on the APC SUA1000RMI1U + WBEXTWAR3YR-SP-03, Double-conversion (Online) on the CyberPower OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. Input frequency: 47/63 Hz on the APC SUA1000RMI1U + WBEXTWAR3YR-SP-03, 40/70 Hz on the CyberPower OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • UPS topology
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:Line-Interactive
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
  • Output power capacity
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:1 kVA
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:640 W
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2400 W
  • Input frequency
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:47/63 Hz
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:40/70 Hz
  • Output operation voltage (min)
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:230 V
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:208 V
  • Output operation voltage (max)
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:230 V
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Power plug
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:C14 coupler
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C19 coupler
  • AC outlets quantity
    • SUA1000RMI1U + WBEXTWAR3YR-SP-03:6 AC outlet(s)
    • OLS3000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:8 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of SUA1000RMI1U + WBEXTWAR3YR-SP-03, OLS3000ERT2U
65 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1 kVA3 kVA
Output powerDiffers640 W2400 W
Input operation voltage (min)Known for one151 VUnknown — not stated by the source
Input operation voltage (max)Known for one302 VUnknown — not stated by the source
Input frequencyDiffers47/63 Hz40/70 Hz
Output operation voltage (min)Differs230 V208 V
Output operation voltage (max)Differs230 V240 V
Output frequency regulationKnown for one47 - 63 HzUnknown — not stated by the source
Output voltage regulationKnown for one5%Unknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one480 JUnknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source95%
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm modesKnown for oneUnknown — not stated by the sourceBattery replacement
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
Power plugDiffersC14 couplerC19 coupler
AC outlets quantityDiffers6 AC outlet(s)8 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery3 differ
Typical backup time at full loadDiffers5.4 min5 min
Typical backup time at half loadDiffers14.5 min14 min
Battery recharge timeDiffers2 h5 h
Battery capacityKnown for oneUnknown — not stated by the source8.5 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source6
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design3 differ
Form factorDiffersRackmountRackmount/Tower
Rack capacityDiffers1U2U
LED indicatorsDiffersYesBattery replacement
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, GOST, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm438 mm
DepthDiffers660 mm610 mm
HeightDiffers44 mm88 mm
WeightDiffers21.8 kg27.6 kg
Packaging dataidentical
Package widthKnown for one559 mmUnknown — not stated by the source
Package depthKnown for one775 mmUnknown — not stated by the source
Package heightKnown for one191 mmUnknown — not stated by the source
Package weightKnown for one25.4 kgUnknown — not stated by the source
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel Business Edition

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons