Key differences

The APC SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 0.8 kVA more output power capacity than the CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (3 kVA vs 2.2 kVA). The APC SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 880 W more output power than the CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (2880 W vs 2000 W). The CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA has 70 V more input operation voltage (min) than the APC SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (190 V vs 120 V). Waveform: Sine on the APC SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, Pure sine on the CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA. Input frequency: 50/60 Hz on the APC SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, 40/70 Hz on the CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA.

  • Output power capacity
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2.2 kVA
  • Output power
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2880 W
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2000 W
  • Waveform
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Sine
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:Pure sine
  • Input operation voltage (min)
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:120 V
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:190 V
  • Input operation voltage (max)
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:125 V
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:300 V
  • Input frequency
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:40/70 Hz
  • Output operation voltage (min)
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:120 V
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:200 V
  • Output operation voltage (max)
    • SRTL3KRM1UC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:125 V
    • OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of SRTL3KRM1UC, OL2200ERTXL2U
77 specifications
Features8 differ
Output power capacityDiffers3 kVA2.2 kVA
Output powerDiffers2880 W2000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs120 V190 V
Input operation voltage (max)Differs125 V300 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs120 V200 V
Output operation voltage (max)Differs125 V240 V
Maximum currentKnown for oneUnknown — not stated by the source11 A
Surge energy ratingKnown for oneUnknown — not stated by the source1335 J
Response timeKnown for oneUnknown — not stated by the source0 ms
Heat dissipationKnown for oneUnknown — not stated by the source1139 BTU/h
Output power factorKnown for oneUnknown — not stated by the source0.9
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Total Harmonic Distortion (THD) (linear load)Known for oneUnknown — not stated by the source3%
Total Harmonic Distortion (THD) (non-linear load)Known for oneUnknown — not stated by the source5%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
EfficiencyKnown for one93%Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersNEMA L5-30RC13 coupler, C19 coupler
Power plugDiffersNEMA L5-30PC20 coupler
AC outlets quantityDiffers6 AC outlet(s)9 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
USB portKnown for oneYesUnknown — not stated by the source
USB port typeKnown for oneUSB Type-AUnknown — not stated by the source
Battery2 differ
Battery technologyDiffersLithium-Ion (Li-Ion)Sealed Lead Acid (VRLA)
Battery voltageKnown for oneUnknown — not stated by the source72 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source6.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source20 min
Battery recharge timeDiffers1.5 h5 h
Charging currentKnown for oneUnknown — not stated by the source1 A
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design5 differ
Form factorDiffersRackmountRackmount/Tower
Product colourDiffersGreyBlack
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Rack capacityDiffers1U2U
Cable lengthDiffers2.44 m3 m
Cooling typeDiffersPassiveActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions3 differ
Storage temperature (T-T)Differs-15 - 45 °C-20 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Operating altitudeDiffers0 - 3048 m0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourceSerial, USB cable
ManualKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHSCE, RoHS
Sustainabilityidentical
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Doesn't containKnown for oneMercuryUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm433 mm
DepthDiffers560 mm600 mm
HeightDiffers43 mm88 mm
WeightDiffers15.9 kg31 kg
Packaging data4 differ
Package widthDiffers564 mm565 mm
Package depthDiffers764 mm880 mm
Package heightDiffers278.2 mm240 mm
Package weightDiffers24.2 kg39.5 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceRBP0076