Product comparison · 2 uninterruptible power supplies (upss)

APC SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05 vs CyberPower OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA

Add a product
  • 42specifications compared
  • 25differ
  • 17identical
  • 27known for one product only

Key differences

  • UPS topology
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:Line-Interactive
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:Double-conversion (Online)
  • Output power capacity
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:3 kVA
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8 kVA
  • Output power
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:2700 W
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:7200 W
  • Input operation voltage (min)
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:140 V
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:120 V
  • Input operation voltage (max)
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:280 V
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:240 V
  • Input frequency
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:47/63 Hz
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:40/70 Hz
  • Output operation voltage (min)
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:208 V
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:200 V
  • Surge energy rating
    • SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05:645 J
    • OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:2670 J

Side by side

Differences highlightedShow differences only (on)
Comparison of SMX3000RMHV2UNC + WBEXTWAR3YR-SP-05, OL8KRT3UHW
69 specifications
Features9 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers3 kVA8 kVA
Output powerDiffers2700 W7200 W
Input operation voltage (min)Differs140 V120 V
Input operation voltage (max)Differs280 V240 V
Input frequencyDiffers47/63 Hz40/70 Hz
Output operation voltage (min)Differs208 V200 V
Surge energy ratingDiffers645 J2670 J
Power factorKnown for oneUnknown — not stated by the source0.9
Input power factorKnown for oneUnknown — not stated by the source0.99
Crest factorKnown for oneUnknown — not stated by the source3:1
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceNetwork, Telephone
Power protection featuresDiffersOverloadOverload, Short circuit
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement
Output frequency regulationKnown for one47 - 63 HzUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
EfficiencyKnown for one98.5%Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerTerminal
AC outlets quantityDiffers9 AC outlet(s)1 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Battery3 differ
Battery capacityKnown for oneUnknown — not stated by the source12 VAh
Number of batteries supportedKnown for oneUnknown — not stated by the source20
Typical backup time at full loadDiffers6.25 min6 min
Typical backup time at half loadDiffers18 min13 min
Battery recharge timeDiffers3 h5 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1290X20
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design2 differ
Housing materialKnown for oneUnknown — not stated by the sourceSteel
Rack capacityDiffers2U6U
LED indicatorsDiffersYesPower, Battery replacement
Cable lengthKnown for one2.44 mUnknown — not stated by the source
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, FCC Part 15 Class A, GOST, IRAM, UL 1778, VDEUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Weight & dimensions4 differ
WidthDiffers432 mm433 mm
DepthDiffers667 mm820 mm
HeightDiffers85 mm264 mm
WeightDiffers37.3 kg104.5 kg
Packaging data4 differ
Package widthDiffers596 mm620 mm
Package depthDiffers869 mm1120 mm
Package heightDiffers243 mm650 mm
Package weightDiffers45.4 kg131.2 kg
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.