Product comparison · 2 uninterruptible power supplies (upss)

APC SMX3000LV uninterruptible power supply (UPS) 3 kVA vs APC SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA

Add a product
  • 36specifications compared
  • 21differ
  • 15identical
  • 27known for one product only

Key differences

  • Output power capacity
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:3 kVA
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:5 kVA
  • Output power
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:2700 W
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:3500 W
  • Input operation voltage (min)
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:70 V
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:100 V
  • Input operation voltage (max)
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:153 V
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:280 V
  • Input frequency
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:50/60 Hz
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:45/65 Hz
  • Surge energy rating
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:540 J
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:555 J
  • Efficiency
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:97.5%
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:92%
  • Output voltage Total Harmonic Distortion (THD)
    • SMX3000LV uninterruptible power supply (UPS) 3 kVA:5%
    • SURTD5000RMXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:3%

Side by side

Differences highlightedShow differences only (off)
Comparison of SMX3000LV, SURTD5000RMXLI
63 specifications
Features8 differ
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
Output power capacityDiffers3 kVA5 kVA
Output powerDiffers2700 W3500 W
WaveformSineSine
Input operation voltage (min)Differs70 V100 V
Input operation voltage (max)Differs153 V280 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source220 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Surge energy ratingDiffers540 J555 J
EfficiencyDiffers97.5%92%
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)Differs5%3%
Noise level55 dB55 dB
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)YesYes
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15R, NEMA 5–20R, NEMA L5-30RC13 coupler, C19 coupler
Power plugDiffersNEMA L5-30PTerminal
AC outlets quantity10 AC outlet(s)10 AC outlet(s)
Number of output IEC jumpersKnown for oneUnknown — not stated by the source4
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supportedDiffers12
Typical backup time at full loadKnown for oneUnknown — not stated by the source6.3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source18.2 min
Battery recharge timeDiffers3 h2.50 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmount/TowerRackmount
Product colourBlackBlack
Rack capacityDiffers2U3U
LED indicatorsYesYes
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Cable lengthKnown for one2.44 mUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersBSMI, CSA, EN 50091-2, EN 55022 Class A, FCC Part 15 Class A, NOM, TUV, UL 1778, VCCI Class A REACH UL 1449C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, OSHPD, UL 1778, VDE
Weight & dimensions4 differ
WidthDiffers178 mm432 mm
DepthDiffers483 mm660 mm
HeightDiffers432 mm130 mm
WeightDiffers38.6 kg54.5 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source603 mm
Package depthKnown for oneUnknown — not stated by the source980 mm
Package heightKnown for oneUnknown — not stated by the source347 mm
Package weightKnown for oneUnknown — not stated by the source63.6 kg
Other features2 differ
Number of phasesKnown for oneUnknown — not stated by the source1
Output connectionsKnown for oneUnknown — not stated by the source8 x IEC 320 C13 & 2 x IEC 320 C19
Input connection typeKnown for oneUnknown — not stated by the sourceHardWire 3-wire
Management platformKnown for oneUnknown — not stated by the sourceSNMP
Nominal input voltageDiffers120 V230 V
Nominal output voltageDiffers120 V230 V
Communication options, slotKnown for oneUnknown — not stated by the sourceSmartSlot
Output connection typeKnown for one6 x NEMA 5-15R & 3 x NEMA 5-20R & 1 x NEMA L5-30RUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons