  • Output power capacity
    • SMX2200HV + WBEXTWAR3YR-SP-04:2.2 kVA
    • Liebert GXT3 On-Line RT 8000VA:8 kVA
  • Output power
    • SMX2200HV + WBEXTWAR3YR-SP-04:1980 W
    • Liebert GXT3 On-Line RT 8000VA:7200 W
  • Input operation voltage (min)
    • SMX2200HV + WBEXTWAR3YR-SP-04:140 V
    • Liebert GXT3 On-Line RT 8000VA:120 V
  • Input operation voltage (max)
    • SMX2200HV + WBEXTWAR3YR-SP-04:280 V
    • Liebert GXT3 On-Line RT 8000VA:208 V
  • Input frequency
    • SMX2200HV + WBEXTWAR3YR-SP-04:50/60 Hz
    • Liebert GXT3 On-Line RT 8000VA:40/70 Hz
  • Output operation voltage (min)
    • SMX2200HV + WBEXTWAR3YR-SP-04:208 V
    • Liebert GXT3 On-Line RT 8000VA:100 V
  • Output operation voltage (max)
    • SMX2200HV + WBEXTWAR3YR-SP-04:240 V
    • Liebert GXT3 On-Line RT 8000VA:127 V
  • Power plug
    • SMX2200HV + WBEXTWAR3YR-SP-04:C20 coupler
    • Liebert GXT3 On-Line RT 8000VA:Terminal

Side by side

Differences highlightedShow differences only (on)
Comparison of SMX2200HV + WBEXTWAR3YR-SP-04, Liebert GXT3 On-Line RT 8000VA
48 specifications
Features7 differ
Output power capacityDiffers2.2 kVA8 kVA
Output powerDiffers1980 W7200 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs140 V120 V
Input operation voltage (max)Differs280 V208 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs208 V100 V
Output operation voltage (max)Differs240 V127 V
Output frequency regulationKnown for one3 HzUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one645 JUnknown — not stated by the source
EfficiencyKnown for one98.1%Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Ports & interfaces1 differ
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Power plugDiffersC20 couplerTerminal
AC outlets quantityKnown for one10 AC outlet(s)Unknown — not stated by the source
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Design1 differ
Rack capacityDiffers4U6U
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 45 °C-15 - 50 °C
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers178 mm430 mm
DepthDiffers483 mm672 mm
HeightDiffers432 mm261 mm
WeightDiffers38.6 kg35.5 kg
Packaging dataidentical
Package widthKnown for one586 mmUnknown — not stated by the source
Package depthKnown for one633 mmUnknown — not stated by the source
Package heightKnown for one330 mmUnknown — not stated by the source
Package weightKnown for one47.7 kgUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneAPCRBC143Unknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source1
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-UL