Product comparison · 2 uninterruptible power supplies (upss)

APC Galaxy VS UPS 100kW vs Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA

Add a product
  • 18specifications compared
  • 15differ
  • 3identical
  • 26known for one product only

Key differences

The APC Galaxy VS UPS 100kW has 85 kVA more output power capacity than the Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA (100 kVA vs 15 kVA). The APC Galaxy VS UPS 100kW has 86,500 W more output power than the Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA (100000 W vs 13500 W). The APC Galaxy VS UPS 100kW has 140 V more input operation voltage (min) than the Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA (340 V vs 200 V). Input frequency: 40 - 70 Hz on the APC Galaxy VS UPS 100kW, 40/70 Hz on the Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA. Product colour: White on the APC Galaxy VS UPS 100kW, Black on the Vertiv Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA.

  • Output power capacity
    • Galaxy VS UPS 100kW:100 kVA
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:15 kVA
  • Output power
    • Galaxy VS UPS 100kW:100000 W
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:13500 W
  • Input operation voltage (min)
    • Galaxy VS UPS 100kW:340 V
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:200 V
  • Input operation voltage (max)
    • Galaxy VS UPS 100kW:460 V
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:240 V
  • Input frequency
    • Galaxy VS UPS 100kW:40 - 70 Hz
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:40/70 Hz
  • Output operation voltage (min)
    • Galaxy VS UPS 100kW:400 V
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:100 V
  • Heat dissipation
    • Galaxy VS UPS 100kW:11373 BTU/h
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:7965 BTU/h
  • Battery voltage
    • Galaxy VS UPS 100kW:576 V
    • Liebert AS4C0NCJGNNXLKB uninterruptible power supply (UPS) 15 kVA:1.67 V

Side by side

Differences highlightedShow differences only (on)
Comparison of GVSUPS100KRHS, AS4C0NCJGNNXLKB
44 specifications
A

APC

Galaxy VS UPS 100kW

Model GVSUPS100KRHS

View product
Features7 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers100 kVA15 kVA
Output powerDiffers100000 W13500 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs340 V200 V
Input operation voltage (max)Differs460 V240 V
Input frequencyDiffers40 - 70 Hz40/70 Hz
Output operation voltage (min)Differs400 V100 V
Maximum currentKnown for one180 AUnknown — not stated by the source
Heat dissipationDiffers11373 BTU/h7965 BTU/h
Crest factorKnown for one2.5:1Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelKnown for one68 dBUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output voltage regulationKnown for oneUnknown — not stated by the source±3%
EfficiencyKnown for oneUnknown — not stated by the source89.7%
Input power factorKnown for oneUnknown — not stated by the source0.99
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Battery1 differ
Battery technologyKnown for oneLithium-Ion (Li-Ion)Unknown — not stated by the source
Battery voltageDiffers576 V1.67 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source15 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source39 min
Design1 differ
Product colourDiffersWhiteBlack
International Protection (IP) codeKnown for oneIP21Unknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Operational conditions1 differ
Storage temperature (T-T)Known for one-25 - 55 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one10 - 80%Unknown — not stated by the source
Operating altitudeDiffers0 - 1005.84 m0 - 3000 m
Certificates1 differ
Compliance certificatesDiffersRoHSREACH, RoHS, WEEE
Sustainabilityidentical
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers521 mm440 mm
DepthDiffers847 mm850 mm
HeightDiffers1485 mm1240 mm
WeightDiffers290 kg417.3 kg
Packaging dataidentical
Package widthKnown for one640 mmUnknown — not stated by the source
Package depthKnown for one990 mmUnknown — not stated by the source
Package heightKnown for one1680 mmUnknown — not stated by the source
Package weightKnown for one315 kgUnknown — not stated by the source
Logistics dataidentical
Warranty periodKnown for one1 year(s)Unknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceIEC/EN/AS 62040-1:2008, UL 1778 4th Ed & CSA 22.2 No. 107.1

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.