Product comparison · 2 uninterruptible power supplies (upss)

APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA vs APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up

Add a product
  • 43specifications compared
  • 24differ
  • 19identical
  • 12known for one product only

Key differences

The APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA has 84 kVA more output power capacity than the APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up (100 kVA vs 16 kVA). The APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up has 54,000 W more output power than the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA (144000 W vs 90000 W). The APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA has 73 V more input operation voltage (min) than the APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up (323 V vs 250 V). Input frequency: 45/65 Hz on the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA, 40/70 Hz on the APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up. Output frequency: 50 Hz on the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA, 50/60 Hz on the APC Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up.

  • Output power capacity
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:100 kVA
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:16 kVA
  • Output power
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:90000 W
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:144000 W
  • Input operation voltage (min)
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:323 V
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:250 V
  • Input operation voltage (max)
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:477 V
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:600 V
  • Input frequency
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:45/65 Hz
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:40/70 Hz
  • Output frequency
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:50 Hz
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:50/60 Hz
  • Maximum current
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:480 A
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:262 A
  • Output voltage Total Harmonic Distortion (THD)
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:2.5%
    • Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up:3%

Side by side

Differences highlightedShow differences only (off)
Comparison of G55TUPU100HXS, GVMSB160KHS
55 specifications
Features10 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers100 kVA16 kVA
Output powerDiffers90000 W144000 W
WaveformSineSine
Input operation voltage (min)Differs323 V250 V
Input operation voltage (max)Differs477 V600 V
Input frequencyDiffers45/65 Hz40/70 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)415 V415 V
Output frequencyDiffers50 Hz50/60 Hz
Maximum currentDiffers480 A262 A
Number of input phases33
Number of output phases33
EfficiencyKnown for one93%Unknown — not stated by the source
Input power factor11
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)Differs2.5%3%
Input current Total Harmonic Distortion (THD)3%3%
Noise levelDiffers63 dB65 dB
Power protection featuresDiffersOverload, Short circuitOverload
Auto-restartKnown for oneYesUnknown — not stated by the source
ECO modeKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)Hard Wire 3-wire (3PH + G)
Serial interfaceYesYes
SmartSlotYesYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-485
Batteryidentical
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorTowerTower
Product colourDiffersGreyWhite
Display typeLCDLCD
LED indicatorsYesYes
International Protection (IP) codeDiffersIP20, IP32IP20
Housing materialKnown for oneUnknown — not stated by the sourceSteel
Operational conditions2 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-20 - 45 °C-25 - 55 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 1000 m0 - 1000 m
Non-operating altitudeDiffers0 - 12000 m0 - 14763 m
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideYesYes
Certificates1 differ
CertificationDiffersCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDEC-tick, CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IBC 2012 and CBC2013 to Sds=2.02g , ISTA 2B, OSHPD, RCM, UL 1778
Weight & dimensions4 differ
WidthDiffers712 mm1052 mm
DepthDiffers855 mm854 mm
HeightDiffers2130 mm1970 mm
WeightDiffers520 kg699 kg
Packaging data4 differ
Package widthDiffers1010 mm1490 mm
Package depthDiffers1050 mm1052 mm
Package heightDiffers2260 mm2156 mm
Package weightDiffers540 kg744.5 kg
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.