Product comparison · 2 uninterruptible power supplies (upss)

APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA vs APC G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA

Add a product
  • 49specifications compared
  • 9differ
  • 40identical
  • 0known for one product only

Key differences

The APC G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 20 kVA more output power capacity than the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA (120 kVA vs 100 kVA). The APC G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 18,000 W more output power than the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA (108000 W vs 90000 W). The APC G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 2% more input current Total Harmonic Distortion (THD) than the APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA (5% vs 3%).

  • Output power capacity
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:100 kVA
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:120 kVA
  • Output power
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:90000 W
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:108000 W
  • Input current Total Harmonic Distortion (THD)
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:3%
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:5%
  • Height
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:2130 mm
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:2180 mm
  • Weight
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:520 kg
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:556 kg
  • Package width
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:1010 mm
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:1080 mm
  • Package depth
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:1050 mm
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:1200 mm
  • Package height
    • G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:2260 mm
    • G55TUPU120HXS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:2300 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of G55TUPU100HXS, G55TUPU120HXS
49 specifications
Features3 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers100 kVA120 kVA
Output powerDiffers90000 W108000 W
WaveformSineSine
Input operation voltage (min)323 V323 V
Input operation voltage (max)477 V477 V
Input frequency45/65 Hz45/65 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)415 V415 V
Output frequency50 Hz50 Hz
Maximum current480 A480 A
Number of input phases33
Number of output phases33
Efficiency93%93%
Input power factor11
Crest factor3:13:1
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)2.5%2.5%
Input current Total Harmonic Distortion (THD)Differs3%5%
Noise level63 dB63 dB
Power protection featuresOverload, Short circuitOverload, Short circuit
Auto-restartYesYes
Ports & interfacesidentical
AC outlet typesHard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)
Serial interfaceYesYes
SmartSlotYesYes
Batteryidentical
Hot-swap batteryYesYes
Automatic battery testYesYes
Designidentical
Form factorTowerTower
Product colourGreyGrey
Display typeLCDLCD
LED indicatorsYesYes
International Protection (IP) codeIP20, IP32IP20, IP32
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-20 - 45 °C-20 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 1000 m0 - 1000 m
Non-operating altitude0 - 12000 m0 - 12000 m
Packaging contentidentical
ManualYesYes
Quick installation guideYesYes
Certificatesidentical
CertificationCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDECE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE
Weight & dimensions2 differ
Width712 mm712 mm
Depth855 mm855 mm
HeightDiffers2130 mm2180 mm
WeightDiffers520 kg556 kg
Packaging data4 differ
Package widthDiffers1010 mm1080 mm
Package depthDiffers1050 mm1200 mm
Package heightDiffers2260 mm2300 mm
Package weightDiffers540 kg610 kg