The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 8.6 kVA more output power capacity than the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA (10 kVA vs 1.4 kVA). The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 9,300 W more output power than the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA (10000 W vs 700 W). The APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA has 40 V more input operation voltage (min) than the Salicru SLC 10000 TWIN PRO3 DUAL B1 (150 V vs 110 V). UPS topology: Line-Interactive on the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA, Double-conversion (Online) on the Salicru SLC 10000 TWIN PRO3 DUAL B1. Input frequency: 50/60 Hz on the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA, 40 - 70 Hz on the Salicru SLC 10000 TWIN PRO3 DUAL B1.

  • UPS topology
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:Line-Interactive
    • SLC 10000 TWIN PRO3 DUAL B1:Double-conversion (Online)
  • Output power capacity
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:1.4 kVA
    • SLC 10000 TWIN PRO3 DUAL B1:10 kVA
  • Output power
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:700 W
    • SLC 10000 TWIN PRO3 DUAL B1:10000 W
  • Input operation voltage (min)
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:150 V
    • SLC 10000 TWIN PRO3 DUAL B1:110 V
  • Input operation voltage (max)
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:280 V
    • SLC 10000 TWIN PRO3 DUAL B1:276 V
  • Input frequency
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:50/60 Hz
    • SLC 10000 TWIN PRO3 DUAL B1:40 - 70 Hz
  • Input power factor
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:0.5
    • SLC 10000 TWIN PRO3 DUAL B1:0.99
  • Noise level
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:45 dB
    • SLC 10000 TWIN PRO3 DUAL B1:60 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of BX1400U-MS, SLC 10000 TWIN PRO3 DUAL B1
79 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.4 kVA10 kVA
Output powerDiffers700 W10000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs150 V110 V
Input operation voltage (max)Differs280 V276 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output frequency regulationKnown for one50/60 HzUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one6 AUnknown — not stated by the source
Surge energy ratingKnown for one273 JUnknown — not stated by the source
Hold time (max)Known for one10 msUnknown — not stated by the source
Hold time (min)Known for one8 msUnknown — not stated by the source
EfficiencyKnown for one97.4%Unknown — not stated by the source
Input power factorDiffers0.50.99
Noise levelDiffers45 dB60 dB
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, ModemUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneOverload alarmUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage, Under voltage, Overheating
Maximum number of paralleling UPSsKnown for oneUnknown — not stated by the source3
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
USB portYesYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Parallel ports quantityKnown for oneUnknown — not stated by the source1
HDMI ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Calcium (Pb-Ca)
Battery capacityKnown for one165 VAhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Number of batteries supportedKnown for one2Unknown — not stated by the source
Typical backup time at full loadKnown for one2.4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one11.2 minUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Charging currentKnown for oneUnknown — not stated by the source12 A
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorTowerTower
Product colourBlackBlack
Cable lengthKnown for one1.22 mUnknown — not stated by the source
Display typeDiffersLEDLCD
LED indicatorsKnown for oneBattery replacementUnknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 3000 m0 - 30000 m
Non-operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneA-tick, C-tick, CE, IEC 62040-1-1, TelepermitUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers130 mm225 mm
DepthDiffers336 mm492 mm
HeightDiffers215 mm589 mm
WeightDiffers12 kg59.5 kg
Packaging dataidentical
Bundled softwareKnown for onePowerChute Personal EditionUnknown — not stated by the source
Package widthKnown for one245 mmUnknown — not stated by the source
Package depthKnown for one440 mmUnknown — not stated by the source
Package heightKnown for one295 mmUnknown — not stated by the source
Package weightKnown for one12.9 kgUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Type of input protection requiredKnown for one3-pole circuit breakerUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.