Product comparison · 2 solar inverters

Salicru EQX2 4002-HT vs Salicru EQX2 6002-HSX

Add a product
  • 48specifications compared
  • 14differ
  • 34identical
  • 1known for one product only

Key differences

The Salicru EQX2 6002-HSX has 1.98 kVA more output power capacity (max) than the Salicru EQX2 4002-HT (6.6 kVA vs 4.62 kVA). The Salicru EQX2 6002-HSX has 3,200 W more maximum input power (DC) than the Salicru EQX2 4002-HT (9600 W vs 6400 W). The Salicru EQX2 6002-HSX has 2,000 W more maximum power than the Salicru EQX2 4002-HT (6000 W vs 4000 W). MPP voltage range: 100 - 850 V on the Salicru EQX2 4002-HT, 100 - 550 V on the Salicru EQX2 6002-HSX.

  • Output power capacity (max)
    • EQX2 4002-HT:4.62 kVA
    • EQX2 6002-HSX:6.6 kVA
  • MPP voltage range
    • EQX2 4002-HT:100 - 850 V
    • EQX2 6002-HSX:100 - 550 V
  • Maximum input power (DC)
    • EQX2 4002-HT:6400 W
    • EQX2 6002-HSX:9600 W
  • Maximum power
    • EQX2 4002-HT:4000 W
    • EQX2 6002-HSX:6000 W
  • DC input voltage
    • EQX2 4002-HT:1000 V
    • EQX2 6002-HSX:600 V
  • Network voltage
    • EQX2 4002-HT:400 V
    • EQX2 6002-HSX:230 V
  • Output current
    • EQX2 4002-HT:5.8 A
    • EQX2 6002-HSX:26.1 A
  • Short-circuit current per MPPT (max)
    • EQX2 4002-HT:18 A
    • EQX2 6002-HSX:20 A

Side by side

Differences highlightedShow differences only (on)
Comparison of EQX2 4002-HT, EQX2 6002-HSX
49 specifications
Features14 differ
Output power capacity (max)Differs4.62 kVA6.6 kVA
MPP voltage rangeDiffers100 - 850 V100 - 550 V
Maximum input power (DC)Differs6400 W9600 W
Maximum powerDiffers4000 W6000 W
DC input voltageDiffers1000 V600 V
Network voltageDiffers400 V230 V
Output currentDiffers5.8 A26.1 A
Short-circuit current per MPPT (max)Differs18 A20 A
Starting voltageDiffers150 V80 V
Number of maximum power point tracking (MPPT)Differs21
Maximum input current per MPPTDiffers13 A15 A
EfficiencyDiffers98.1%97.6%
Efficiency (EU)Differs97.3%97%
CertificationDiffersEN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-1/2/14/30,UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001EN 61000-6-2/3, IEC 62109-IEC EN UNE 616831/2 / EN 61000-6-2/3, IEC EN UNE 60068-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001
Designidentical
Cooling typeKnown for onePassiveUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More solar inverter comparisons

All solar inverter comparisons