Product comparison · 2 security door controllers

Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 vs Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485

Add a product
  • 12specifications compared
  • 12differ
  • 0identical
  • 17known for one product only

Key differences

The Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 has 5 - 90% more operating relative humidity (H-H) than the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 (5 - 90% vs 0 - 90%). The Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 has 62 mm more depth than the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 (106 mm vs 44 mm). The Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 has 109.5 mm more height than the Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 (159.5 mm vs 50 mm). Only the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 has built-in UPS. Case design: Bare on the Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485, Housing on the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485.

  • Case design
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:Bare
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:Housing
  • Maximum number of doors
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:2 door(s)
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:4 door(s)
  • Built-in UPS
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:No
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:Yes
  • Interface
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:RJ-45 / RS-485
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:RS-485
  • Number of users
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:100000 user(s)
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:20000 user(s)
  • DC voltage range
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:12 V
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 12 V
  • Operating temperature (T-T)
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:-30 - 60 °C
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 50 °C
  • Operating relative humidity (H-H)
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:5 - 90%
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 90%

Side by side

Differences highlightedShow differences only (off)
Comparison of DHI-ASC2202B-S, SSA-S2101
29 specifications
Technical details5 differ
Case designDiffersBareHousing
Maximum number of doorsDiffers2 door(s)4 door(s)
Built-in UPSDiffersNoYes
InterfaceDiffersRJ-45 / RS-485RS-485
Exit button supportedKnown for oneYesUnknown — not stated by the source
Number of usersDiffers100000 user(s)20000 user(s)
Number of programmable holidaysKnown for oneUnknown — not stated by the source100
Performanceidentical
Ethernet LANKnown for oneYesUnknown — not stated by the source
Ethernet LAN data ratesKnown for one10,100 Mbit/sUnknown — not stated by the source
Wiegand interfaceKnown for oneYesUnknown — not stated by the source
Number of Wiegand readers supportedKnown for one2Unknown — not stated by the source
Alarm input channelsKnown for one2Unknown — not stated by the source
CertificationKnown for oneCE/FCC/ULUnknown — not stated by the source
Power1 differ
Operating voltageKnown for one12 VUnknown — not stated by the source
Operating currentKnown for one1 AUnknown — not stated by the source
Power consumption (typical)Known for one24 WUnknown — not stated by the source
DC voltage rangeDiffers12 V0 - 12 V
Power consumptionKnown for oneUnknown — not stated by the source420 mA
Ports & interfacesidentical
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
RS-485 portsKnown for one3Unknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-30 - 60 °C0 - 50 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 90%
Weight & dimensions4 differ
DepthDiffers106 mm44 mm
HeightDiffers50 mm159.5 mm
WeightDiffers400 g710 g
WidthDiffers155 mm191.5 mm
Packaging dataidentical
Package depthKnown for one141 mmUnknown — not stated by the source
Package heightKnown for one87 mmUnknown — not stated by the source
Package widthKnown for one190 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More security door controller comparisons

All security door controller comparisons