Product comparison · 2 security door controllers

Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485 vs Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485

Add a product
  • 12specifications compared
  • 10differ
  • 2identical
  • 7known for one product only

Key differences

The Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485 has 80 mA more power consumption than the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 (500 mA vs 420 mA). The Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485 has 166 mm more depth than the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 (210 mm vs 44 mm). The Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485 has 108.3 mm more height than the Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485 (159.5 mm vs 51.2 mm). Case design: Bare on the Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485, Housing on the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485. Maximum number of doors: 9 door(s) on the Dahua Technology ASC2102B-T security door controller Bare 9 door(s) RS-485, 4 door(s) on the Samsung SSA-S2101 security door controller Housing 4 door(s) RS-485.

  • Case design
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:Bare
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:Housing
  • Maximum number of doors
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:9 door(s)
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:4 door(s)
  • Power consumption
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:500 mA
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:420 mA
  • DC voltage range
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:12 V
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 12 V
  • Operating temperature (T-T)
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:-30 - 60 °C
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 50 °C
  • Operating relative humidity (H-H)
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:0 - 95%
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:0 - 90%
  • Depth
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:210 mm
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:44 mm
  • Height
    • ASC2102B-T security door controller Bare 9 door(s) RS-485:51.2 mm
    • SSA-S2101 security door controller Housing 4 door(s) RS-485:159.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ASC2102B-T, SSA-S2101
19 specifications
Technical details2 differ
Case designDiffersBareHousing
Maximum number of doorsDiffers9 door(s)4 door(s)
InterfaceRS-485RS-485
Card holders quantityKnown for one20000Unknown — not stated by the source
Event capacityKnown for one30000Unknown — not stated by the source
Number of users20000 user(s)20000 user(s)
Built-in UPSKnown for oneUnknown — not stated by the sourceYes
Number of programmable holidaysKnown for oneUnknown — not stated by the source100
Performanceidentical
Internal memoryKnown for one0.016 GBUnknown — not stated by the source
CertificationKnown for oneCE, FCCUnknown — not stated by the source
Power2 differ
Power consumptionDiffers500 mA420 mA
DC voltage rangeDiffers12 V0 - 12 V
Ports & interfacesidentical
RS-485 portsKnown for one1Unknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-30 - 60 °C0 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Weight & dimensions4 differ
DepthDiffers210 mm44 mm
HeightDiffers51.2 mm159.5 mm
WeightDiffers500 g710 g
WidthDiffers116 mm191.5 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.