Product comparison · 2 security door controllers

Dahua Technology ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485 vs Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485

Add a product
  • 15specifications compared
  • 7differ
  • 8identical
  • 22known for one product only

Key differences

The Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 has 2 more RS-485 ports than the Dahua Technology ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485 (3 vs 1). The Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 has 55 mm more depth than the Dahua Technology ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485 (106 mm vs 51 mm). The Dahua Technology ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485 has 48 mm more height than the Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 (98 mm vs 50 mm). Only the Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485 has wiegand interface. DC voltage range: 9 - 15 V on the Dahua Technology ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485, 12 V on the Dahua Technology DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485.

  • Wiegand interface
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:No
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:Yes
  • DC voltage range
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:9 - 15 V
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:12 V
  • RS-485 ports
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:1
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:3
  • Depth
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:51 mm
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:106 mm
  • Height
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:98 mm
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:50 mm
  • Weight
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:450 g
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:400 g
  • Width
    • ASC1202B-S security door controller 2 door(s) RJ-45 / RS-485:156 mm
    • DHI-ASC2202B-S security door controller Bare 2 door(s) RJ-45 / RS-485:155 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ASC1202B-S, DHI-ASC2202B-S
37 specifications
Technical detailsidentical
Case designKnown for oneUnknown — not stated by the sourceBare
Maximum number of doors2 door(s)2 door(s)
Built-in UPSKnown for oneUnknown — not stated by the sourceNo
InterfaceRJ-45 / RS-485RJ-45 / RS-485
Exit button supportedYesYes
Number of usersKnown for oneUnknown — not stated by the source100000 user(s)
Card holders quantityKnown for one100000Unknown — not stated by the source
Event capacityKnown for one150000Unknown — not stated by the source
Compliance certificatesKnown for oneCE, Federal Communications Commission (FCC)Unknown — not stated by the source
Scheduled door armingKnown for oneYesUnknown — not stated by the source
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Performance1 differ
Ethernet LANYesYes
Ethernet LAN data rates10,100 Mbit/s10,100 Mbit/s
Wiegand interfaceDiffersNoYes
Number of Wiegand readers supportedKnown for oneUnknown — not stated by the source2
Alarm input channels22
CertificationKnown for oneUnknown — not stated by the sourceCE/FCC/UL
Processor operating modesKnown for one32-bitUnknown — not stated by the source
Internal memoryKnown for one0.016 GBUnknown — not stated by the source
Number of built-in relaysKnown for one4Unknown — not stated by the source
Power1 differ
Operating voltageKnown for oneUnknown — not stated by the source12 V
Operating currentKnown for oneUnknown — not stated by the source1 A
Power consumption (typical)Known for oneUnknown — not stated by the source24 W
DC voltage rangeDiffers9 - 15 V12 V
Power consumptionKnown for one500 mAUnknown — not stated by the source
Ports & interfaces1 differ
Ethernet LAN (RJ-45) ports11
RS-485 portsDiffers13
Operational conditionsidentical
Operating temperature (T-T)-30 - 60 °C-30 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 90%
Weight & dimensions4 differ
DepthDiffers51 mm106 mm
HeightDiffers98 mm50 mm
WeightDiffers450 g400 g
WidthDiffers156 mm155 mm
Packaging dataidentical
Package depthKnown for oneUnknown — not stated by the source141 mm
Package heightKnown for oneUnknown — not stated by the source87 mm
Package widthKnown for oneUnknown — not stated by the source190 mm
Logistics dataidentical
Quantity per packKnown for one1 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More security door controller comparisons

All security door controller comparisons