Product comparison · 2 rack cooling equipment

APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier vs Vertiv VRC202KIT-N rack cooling equipment

Add a product
  • 10specifications compared
  • 9differ
  • 1identical
  • 27known for one product only

Key differences

The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 36 U more rack capacity than the Vertiv VRC202KIT-N rack cooling equipment (42U vs 6U). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 16,700 W more input power than the Vertiv VRC202KIT-N rack cooling equipment (20200 W vs 3500 W). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 2 more input phases than the Vertiv VRC202KIT-N rack cooling equipment (3 vs 1). Input voltage: 200 - 240 V on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 230 V on the Vertiv VRC202KIT-N rack cooling equipment. Input frequency: 50 / 60 Hz on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 50-60 Hz on the Vertiv VRC202KIT-N rack cooling equipment.

  • Rack capacity
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:42U
    • VRC202KIT-N rack cooling equipment:6U
  • Input power
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:20200 W
    • VRC202KIT-N rack cooling equipment:3500 W
  • Input voltage
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:200 - 240 V
    • VRC202KIT-N rack cooling equipment:230 V
  • Input frequency
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:50 / 60 Hz
    • VRC202KIT-N rack cooling equipment:50-60 Hz
  • Number of input phases
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:3
    • VRC202KIT-N rack cooling equipment:1
  • Width
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:600 mm
    • VRC202KIT-N rack cooling equipment:442 mm
  • Depth
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1070 mm
    • VRC202KIT-N rack cooling equipment:602 mm
  • Height
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1991 mm
    • VRC202KIT-N rack cooling equipment:264 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD600P, VRC202KIT-N
37 specifications
Performance1 differ
Housing colourBlackBlack
Rack capacityDiffers42U6U
AirflowKnown for one1887.8 l/sUnknown — not stated by the source
Humidification capacityKnown for one3000 ml/hUnknown — not stated by the source
Built-in displayKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Number of power cordsKnown for one1Unknown — not stated by the source
Noise levelKnown for one84 dBUnknown — not stated by the source
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source3500 W
Maximum airflowKnown for oneUnknown — not stated by the source470 cfm
CertificationKnown for oneUnknown — not stated by the sourceCE
Power4 differ
Input powerDiffers20200 W3500 W
Input voltageDiffers200 - 240 V230 V
Input frequencyDiffers50 / 60 Hz50-60 Hz
Number of input phasesDiffers31
CurrentKnown for one78 AUnknown — not stated by the source
Featuresidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one5 - 95 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers600 mm442 mm
DepthDiffers1070 mm602 mm
HeightDiffers1991 mm264 mm
WeightDiffers413 kg23 kg
Packaging dataidentical
Package widthKnown for one1137 mmUnknown — not stated by the source
Package depthKnown for one850 mmUnknown — not stated by the source
Package heightKnown for one2166 mmUnknown — not stated by the source
Package weightKnown for one458 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceChina
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85389099
Shipping (inner) case widthKnown for oneUnknown — not stated by the source74.5 cm
Shipping (inner) case lengthKnown for oneUnknown — not stated by the source83 cm
Shipping (inner) case heightKnown for oneUnknown — not stated by the source46 cm
Shipping (inner) case gross weightKnown for oneUnknown — not stated by the source50 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.