Product comparison · 2 rack cooling equipment

APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier vs Vertiv Liebert HCR51

Add a product
  • 15specifications compared
  • 15differ
  • 0identical
  • 14known for one product only

Key differences

The Vertiv Liebert HCR51 has 281,445.53 l/s more airflow than the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier (283333.33 l/s vs 1887.8 l/s). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 19,100 W more input power than the Vertiv Liebert HCR51 (20200 W vs 1100 W). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 2 more input phases than the Vertiv Liebert HCR51 (3 vs 1). Only the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has built-in display. Housing colour: Black on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, Aluminium on the Vertiv Liebert HCR51.

  • Housing colour
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:Black
    • Liebert HCR51:Aluminium
  • Airflow
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1887.8 l/s
    • Liebert HCR51:283333.33 l/s
  • Built-in display
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:Yes
    • Liebert HCR51:No
  • Input power
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:20200 W
    • Liebert HCR51:1100 W
  • Input voltage
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:200 - 240 V
    • Liebert HCR51:230 V
  • Input frequency
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:50 / 60 Hz
    • Liebert HCR51:50 Hz
  • Number of input phases
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:3
    • Liebert HCR51:1
  • Width
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:600 mm
    • Liebert HCR51:2340 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD600P, HCR51
29 specifications
B

Vertiv

Liebert HCR51

Model HCR51

View product
Performance3 differ
Housing colourDiffersBlackAluminium
Rack capacityKnown for one42UUnknown — not stated by the source
AirflowDiffers1887.8 l/s283333.33 l/s
Humidification capacityKnown for one3000 ml/hUnknown — not stated by the source
Built-in displayDiffersYesNo
Display typeKnown for oneLCDUnknown — not stated by the source
Number of power cordsKnown for one1Unknown — not stated by the source
Noise levelKnown for one84 dBUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceCE
Power4 differ
Input powerDiffers20200 W1100 W
Input voltageDiffers200 - 240 V230 V
Input frequencyDiffers50 / 60 Hz50 Hz
Number of input phasesDiffers31
CurrentKnown for one78 AUnknown — not stated by the source
Featuresidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one5 - 95 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers600 mm2340 mm
DepthDiffers1070 mm1112 mm
HeightDiffers1991 mm910 mm
WeightDiffers413 kg93 kg
Packaging data4 differ
Package widthDiffers1137 mm1195 mm
Package depthDiffers850 mm2420 mm
Package heightDiffers2166 mm1100 mm
Package weightDiffers458 kg143 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.