Product comparison · 2 rack cooling equipment

APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier vs Vertiv Liebert CR012

Add a product
  • 15specifications compared
  • 12differ
  • 3identical
  • 21known for one product only

Key differences

The Vertiv Liebert CR012 has 51,445.53 l/s more airflow than the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier (53333.33 l/s vs 1887.8 l/s). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 16,900 W more input power than the Vertiv Liebert CR012 (20200 W vs 3300 W). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 300 mm more width than the Vertiv Liebert CR012 (600 mm vs 300 mm). Input voltage: 200 - 240 V on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 400 V on the Vertiv Liebert CR012. Input frequency: 50 / 60 Hz on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 50 Hz on the Vertiv Liebert CR012.

  • Airflow
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1887.8 l/s
    • Liebert CR012:53333.33 l/s
  • Input power
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:20200 W
    • Liebert CR012:3300 W
  • Input voltage
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:200 - 240 V
    • Liebert CR012:400 V
  • Input frequency
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:50 / 60 Hz
    • Liebert CR012:50 Hz
  • Width
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:600 mm
    • Liebert CR012:300 mm
  • Depth
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1070 mm
    • Liebert CR012:1100 mm
  • Height
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1991 mm
    • Liebert CR012:2000 mm
  • Weight
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:413 kg
    • Liebert CR012:215 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD600P, CR012
36 specifications
B

Vertiv

Liebert CR012

Model CR012

View product
Performance1 differ
Housing colourBlackBlack
Rack capacityKnown for one42UUnknown — not stated by the source
AirflowDiffers1887.8 l/s53333.33 l/s
Humidification capacityKnown for one3000 ml/hUnknown — not stated by the source
Built-in displayYesYes
Display typeKnown for oneLCDUnknown — not stated by the source
Number of power cordsKnown for one1Unknown — not stated by the source
Noise levelKnown for one84 dBUnknown — not stated by the source
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source13000 W
Air filterKnown for oneUnknown — not stated by the sourceYes
Fan speed controlKnown for oneUnknown — not stated by the sourceYes
Temperature monitoringKnown for oneUnknown — not stated by the sourceYes
Humidifier functionKnown for oneUnknown — not stated by the sourceYes
Reheat functionKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceCE
Power3 differ
Input powerDiffers20200 W3300 W
Input voltageDiffers200 - 240 V400 V
Input frequencyDiffers50 / 60 Hz50 Hz
Number of input phases33
CurrentKnown for one78 AUnknown — not stated by the source
Featuresidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one5 - 95 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers600 mm300 mm
DepthDiffers1070 mm1100 mm
HeightDiffers1991 mm2000 mm
WeightDiffers413 kg215 kg
Packaging data4 differ
Package widthDiffers1137 mm766 mm
Package depthDiffers850 mm1266 mm
Package heightDiffers2166 mm2232 mm
Package weightDiffers458 kg283 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More rack cooling equipment comparisons

All rack cooling equipment comparisons