Product comparison · 2 rack cooling equipment

APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier vs Middle Atlantic 100 CFM Fan Panel

Add a product
  • 10specifications compared
  • 8differ
  • 2identical
  • 23known for one product only

Key differences

The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 40 U more rack capacity than the Middle Atlantic 100 CFM Fan Panel (42U vs 2U). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 57 dB more noise level than the Middle Atlantic 100 CFM Fan Panel (84 dB vs 27 dB). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 117.4 mm more width than the Middle Atlantic 100 CFM Fan Panel (600 mm vs 482.6 mm). Only the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has built-in display. Input voltage: 200 - 240 V on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 220 V on the Middle Atlantic 100 CFM Fan Panel.

  • Rack capacity
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:42U
    • 100 CFM Fan Panel:2U
  • Built-in display
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:Yes
    • 100 CFM Fan Panel:No
  • Noise level
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:84 dB
    • 100 CFM Fan Panel:27 dB
  • Input voltage
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:200 - 240 V
    • 100 CFM Fan Panel:220 V
  • Width
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:600 mm
    • 100 CFM Fan Panel:482.6 mm
  • Depth
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1070 mm
    • 100 CFM Fan Panel:75.2 mm
  • Height
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1991 mm
    • 100 CFM Fan Panel:88.9 mm
  • Package weight
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:458 kg
    • 100 CFM Fan Panel:1.81 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of ACRD600P, IUQFP-4RA
33 specifications
B

Middle Atlantic

100 CFM Fan Panel

Model IUQFP-4RA

View product
Performance3 differ
Rack capacityDiffers42U2U
AirflowKnown for one1887.8 l/sUnknown — not stated by the source
Humidification capacityKnown for one3000 ml/hUnknown — not stated by the source
Built-in displayDiffersYesNo
Display typeKnown for oneLCDUnknown — not stated by the source
Number of power cordsKnown for one1Unknown — not stated by the source
Noise levelDiffers84 dB27 dB
Number of fansKnown for oneUnknown — not stated by the source4 fan(s)
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Maximum airflowKnown for oneUnknown — not stated by the source100 cfm
CertificationKnown for oneUnknown — not stated by the sourceCE
Power1 differ
Input powerKnown for one20200 WUnknown — not stated by the source
Input voltageDiffers200 - 240 V220 V
Input frequencyKnown for one50 / 60 HzUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
CurrentKnown for one78 AUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one5 - 95 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers600 mm482.6 mm
DepthDiffers1070 mm75.2 mm
HeightDiffers1991 mm88.9 mm
WeightKnown for one413 kgUnknown — not stated by the source
Packaging data1 differ
Package widthKnown for one1137 mmUnknown — not stated by the source
Package depthKnown for one850 mmUnknown — not stated by the source
Package heightKnown for one2166 mmUnknown — not stated by the source
Package weightDiffers458 kg1.81 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85389099

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More rack cooling equipment comparisons

All rack cooling equipment comparisons