Product comparison · 2 rack cooling equipment

APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier vs Middle Atlantic 276 CFM Fan Top, 220 - 240VAC for BGR Series

Add a product
  • 7specifications compared
  • 6differ
  • 1identical
  • 25known for one product only

Key differences

The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 49 dB more noise level than the Middle Atlantic 276 CFM Fan Top, 220 - 240VAC for BGR Series (84 dB vs 35 dB). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 31.5 mm more width than the Middle Atlantic 276 CFM Fan Top, 220 - 240VAC for BGR Series (600 mm vs 568.5 mm). The APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has 1,043.3 mm more depth than the Middle Atlantic 276 CFM Fan Top, 220 - 240VAC for BGR Series (1070 mm vs 26.7 mm). Only the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier has built-in display. Input voltage: 200 - 240 V on the APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier, 220 V on the Middle Atlantic 276 CFM Fan Top, 220 - 240VAC for BGR Series.

  • Built-in display
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:Yes
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:No
  • Noise level
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:84 dB
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:35 dB
  • Input voltage
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:200 - 240 V
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:220 V
  • Width
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:600 mm
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:568.5 mm
  • Depth
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1070 mm
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:26.7 mm
  • Height
    • InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz, with humidifier:1991 mm
    • 276 CFM Fan Top, 220 - 240VAC for BGR Series:221.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD600P, IBGR-276FT
32 specifications
Performance2 differ
Housing colourBlackBlack
Rack capacityKnown for one42UUnknown — not stated by the source
AirflowKnown for one1887.8 l/sUnknown — not stated by the source
Humidification capacityKnown for one3000 ml/hUnknown — not stated by the source
Built-in displayDiffersYesNo
Display typeKnown for oneLCDUnknown — not stated by the source
Number of power cordsKnown for one1Unknown — not stated by the source
Noise levelDiffers84 dB35 dB
Number of fansKnown for oneUnknown — not stated by the source4 fan(s)
Maximum airflowKnown for oneUnknown — not stated by the source276 cfm
CertificationKnown for oneUnknown — not stated by the sourceCE,TAA
Power1 differ
Input powerKnown for one20200 WUnknown — not stated by the source
Input voltageDiffers200 - 240 V220 V
Input frequencyKnown for one50 / 60 HzUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
CurrentKnown for one78 AUnknown — not stated by the source
Featuresidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one5 - 95 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers600 mm568.5 mm
DepthDiffers1070 mm26.7 mm
HeightDiffers1991 mm221.5 mm
WeightKnown for one413 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one1137 mmUnknown — not stated by the source
Package depthKnown for one850 mmUnknown — not stated by the source
Package heightKnown for one2166 mmUnknown — not stated by the source
Package weightKnown for one458 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, TAA
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85389099

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.