Key differences

  • Total power
    • 30W Ultra slim design with:30 W
    • 240W Universal AC input / Full range DIN Power Supply:240 W
  • AC input voltage
    • 30W Ultra slim design with:85 - 264 V
    • 240W Universal AC input / Full range DIN Power Supply:90 - 264 V
  • Input current
    • 30W Ultra slim design with:0.8 A
    • 240W Universal AC input / Full range DIN Power Supply:2.5/115VC, 1.3/230VC
  • Efficiency
    • 30W Ultra slim design with:89%
    • 240W Universal AC input / Full range DIN Power Supply:88.5%
  • Hold time
    • 30W Ultra slim design with:30 ms
    • 240W Universal AC input / Full range DIN Power Supply:28 ms
  • Product colour
    • 30W Ultra slim design with:Black
    • 240W Universal AC input / Full range DIN Power Supply:Stainless steel
  • Operating temperature (T-T)
    • 30W Ultra slim design with:-30 - 70 °C
    • 240W Universal AC input / Full range DIN Power Supply:-20 - 70 °C
  • Operating relative humidity (H-H)
    • 30W Ultra slim design with:20 - 90%
    • 240W Universal AC input / Full range DIN Power Supply:20 - 95%

Side by side

Differences highlightedShow differences only (off)
Comparison of DIS-H30-24, DIS-N240-48
19 specifications
Power6 differ
Total powerDiffers30 W240 W
AC input voltageDiffers85 - 264 V90 - 264 V
AC input frequency47 - 63 Hz47 - 63 Hz
Input currentDiffers0.8 A2.5/115VC, 1.3/230VC
Power factorKnown for oneUnknown — not stated by the source0.98
EfficiencyDiffers89%88.5%
Hold timeDiffers30 ms28 ms
Power protection featuresDiffersOver voltage, OverloadOver voltage, Overheating, Overload
Design1 differ
Product colourDiffersBlackStainless steel
Operational conditions2 differ
Operating temperature (T-T)Differs-30 - 70 °C-20 - 70 °C
Storage temperature (T-T)-40 - 85 °C-40 - 85 °C
Operating relative humidity (H-H)Differs20 - 90%20 - 95%
Storage relative humidity (H-H)10 - 95%10 - 95%
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source63 mm
DepthKnown for oneUnknown — not stated by the source113.5 mm
HeightKnown for oneUnknown — not stated by the source125.2 mm
Logistics dataidentical
Harmonized System (HS) code8473302084733020
Other features1 differ
Rise timeDiffers50 ms100 ms
Operating altitudeKnown for one0 - 2000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.