Product comparison · 2 power distribution units (pdus)

Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black vs Vertiv Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black

Add a product
  • 9specifications compared
  • 7differ
  • 2identical
  • 13known for one product only

Key differences

  • Rack capacity
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:2U
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:8 AC outlet(s)
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:20 AC outlet(s)
  • AC outlet types
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:NEMA 5-15R
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:C13 coupler
  • Nominal input voltage
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:120 V
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:100-240 V
  • Maximum current
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:24 A
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:16 A
  • Operating temperature (T-T)
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:32 - 104 °F
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:10 - 45 °C
  • Storage temperature (T-T)
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:-20 - 60 °C
    • Avocent PM3009H power distribution unit (PDU) 20 AC outlet(s) 1U Black:-40 - 65 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of MP2-115A, PM3009H
22 specifications
Design1 differ
PDU typesKnown for oneUnknown — not stated by the sourceMetered, Switched
Rack capacityDiffers2U1U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)20 AC outlet(s)
AC outlet typesDiffersNEMA 5-15RC13 coupler
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3.048 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceHumidity, Temperature
Power2 differ
Nominal input voltageDiffers120 V100-240 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers24 A16 A
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs32 - 104 °F10 - 45 °C
Storage temperature (T-T)Differs-20 - 60 °C-40 - 65 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source56 mm
DepthKnown for oneUnknown — not stated by the source81 mm
HeightKnown for oneUnknown — not stated by the source1321 mm
WeightKnown for oneUnknown — not stated by the source4.99 kg
Certificatesidentical
CertificationKnown for oneUL1778, c-UL, & ISTA Procedure 1A listedUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons