Product comparison · 2 power distribution units (pdus)

Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black vs Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 16specifications compared
  • 14differ
  • 2identical
  • 13known for one product only

Key differences

The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1 U more rack capacity than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (1U vs 0U). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 0.05 m more cable length than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (3.05 m vs 3 m). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 70 A more maximum current than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (100 A vs 30 A). PDU types: Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black, Monitored on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. Mounting: Horizontal on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black, Vertical on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Monitored
  • Rack capacity
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:0U
  • Mounting
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Horizontal
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Vertical
  • AC outlets quantity
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Power plug
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA L14-30P
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:IEC 60309
  • AC outlet types
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-20R, C13 coupler
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Cable length
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:3 m
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:3.05 m
  • Nominal input voltage
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:100 - 240 V
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V

Side by side

Differences highlightedShow differences only (off)
Comparison of MN00X1R1-16MCQ9-3TL14A0A10-S, MN05MGW1-24CF18-8PS15D0A10-S
29 specifications
Design3 differ
PDU typesDiffersBasicMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
On/off switchKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L14-30PIEC 60309
AC outlet typesDiffersNEMA 5-20R, C13 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthDiffers3 m3.05 m
Power3 differ
Nominal input voltageDiffers100 - 240 V208 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers30 A100 A
Load capacityDiffers5700 VA208 VA
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Maximum powerKnown for one5700 WUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance
Compliance certificatesKnown for oneTrade Agreements Act (TAA), UL, cUL, RoHSUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source10 - 45 °C
Weight & dimensions4 differ
WidthDiffers50.8 mm97 mm
DepthDiffers50.8 mm76 mm
HeightDiffers1682.7 mm1683 mm
WeightDiffers6.8 kg8.6 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.