Key differences

  • PDU types
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:Basic
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:Monitored
  • AC outlets quantity
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:24 AC outlet(s)
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:20 AC outlet(s)
  • Output connections
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:20 x C13 & 4 x C19
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:18 x C13 & 2 x C19
  • Certification
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:CE, RoHS, CB
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:CE, RoHS, CB certificate
  • Operating temperature (T-T)
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:0 - 45 °C
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:0 - 60 °C
  • Width
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:1207 mm
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:914 mm
  • Weight
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:3.1 kg
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:4.54 kg
  • Package width
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:1270 mm
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:1042 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19, Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19
27 specifications
Design1 differ
PDU typesDiffersBasicMonitored
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)20 AC outlet(s)
Power plugC20 couplerC20 coupler
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers20 x C13 & 4 x C1918 x C13 & 2 x C19
Featuresidentical
LED indicatorsNoNo
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Management platformKnown for oneUnknown — not stated by the sourceWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTP
Poweridentical
Nominal input voltage230 V230 V
AC input frequency50 Hz50 Hz
Maximum current16 A16 A
Load capacity3600 VA3600 VA
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersCE, RoHS, CBCE, RoHS, CB certificate
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 60 °C
Weight & dimensions2 differ
WidthDiffers1207 mm914 mm
Depth51 mm51 mm
Height51 mm51 mm
WeightDiffers3.1 kg4.54 kg
Packaging data1 differ
Package widthDiffers1270 mm1042 mm
Package depth127 mm127 mm
Package height77 mm77 mm
Package weightKnown for one3.63 kgUnknown — not stated by the source