Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V vs Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309

Add a product
  • 7specifications compared
  • 5differ
  • 2identical
  • 11known for one product only

Key differences

  • Rack capacity
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:0U
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309:0U/1U
  • AC outlets quantity
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:6 AC outlet(s)
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309:9 AC outlet(s)
  • Input connection type
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309:IEC 60309 16A 1P+N+G 6h
  • Nominal input voltage
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:230-400 V
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309:230 V
  • Maximum current
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:96 A
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input input IEC60309:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of 033009061, 036068081
18 specifications
Design1 differ
Rack capacityDiffers0U0U/1U
Housing materialKnown for onePlastic, Steel, ZincUnknown — not stated by the source
Product colourBlack, GreyBlack, Grey
PDU typesKnown for oneUnknown — not stated by the sourceMetered
MountingKnown for oneUnknown — not stated by the sourceHorizontal/Vertical
Ports & interfaces2 differ
AC outlets quantityDiffers6 AC outlet(s)9 AC outlet(s)
Power plugIEC 60309IEC 60309
Input connection typeDiffersIEC60309 3ph/N/PE 6hIEC 60309 16A 1P+N+G 6h
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Featuresidentical
Cable lengthKnown for one2.5 mUnknown — not stated by the source
Cable typeKnown for oneH05V2V2-F 3x4 mm2Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers230-400 V230 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers96 A16 A
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one1147 mmUnknown — not stated by the source
DepthKnown for one44.5 mmUnknown — not stated by the source
HeightKnown for one46 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.