Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18 vs Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V

Add a product
  • 11specifications compared
  • 10differ
  • 1identical
  • 11known for one product only

Key differences

The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 16 A more maximum current than the Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18 (32 A vs 16 A). The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 11.6 mm more width than the Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18 (56 mm vs 44.4 mm). The Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18 has 433 mm more depth than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (483 mm vs 50 mm). Housing material: Brass, Plastic, Steel, Zinc on the Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18, Aluminium on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V. Product colour: Black, Grey on the Vertiv Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18, Black on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V.

  • Housing material
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:Brass, Plastic, Steel, Zinc
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:Aluminium
  • Product colour
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:Black, Grey
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:Black
  • Power plug
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:GST18
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:IEC 60309
  • AC outlet types
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:C13 coupler
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:C19 coupler
  • Input connection type
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:GST18
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:IEC 60309 32A 3P+N+G
  • Nominal input voltage
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:230 V
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:16 A
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:32 A
  • Width
    • Knürr DIS Rack PDU, Safety Standard, 0U/1U, input GST18:44.4 mm
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:56 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 03.618.206.1, MPE-3345-002
22 specifications
Design2 differ
Housing materialDiffersBrass, Plastic, Steel, ZincAluminium
Product colourDiffersBlack, GreyBlack
Rack capacityKnown for oneUnknown — not stated by the source0U
Ports & interfaces3 differ
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
Power plugDiffersGST18IEC 60309
AC outlet typesDiffersC13 couplerC19 coupler
Input connection typeDiffersGST18IEC 60309 32A 3P+N+G
Featuresidentical
Cable lengthKnown for one2.5 mUnknown — not stated by the source
Cable typeKnown for oneH05VV-F 3G 1.5 mm2Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers230 V230-400 V
Maximum currentDiffers16 A32 A
Power protection featuresKnown for oneOver voltageUnknown — not stated by the source
Certificatesidentical
CertificationKnown for one- CE Label in accordance with low voltage directive 2006/95/EEC EMC Directive 2006/108/EEC - Innova-GS - CB-scheme - VDEUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers44.4 mm56 mm
DepthDiffers483 mm50 mm
HeightDiffers45.5 mm826.5 mm
Size (imperial)Known for one48.3 cm (19")Unknown — not stated by the source
Packaging contentidentical
Packaging contentKnown for one1 socket strip 2 mounting bracketsUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 85 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source10 - 90%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons