Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V vs Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12

Add a product
  • 14specifications compared
  • 10differ
  • 4identical
  • 4known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12 has 1 U more rack capacity than the Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V (1U vs 0U). The Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V has 6 A more maximum current than the Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12 (16 A vs 10 A). The Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12 has 100 mm more depth than the Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V (933 mm vs 833 mm). Housing material: Plastic, Steel, Zinc on the Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V, Brass, Plastic, Steel, Zinc on the Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12. AC outlets quantity: 21 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V, 8 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12.

  • Rack capacity
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:0U
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:1U
  • Housing material
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:Plastic, Steel, Zinc
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:Brass, Plastic, Steel, Zinc
  • AC outlets quantity
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:21 AC outlet(s)
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:8 AC outlet(s)
  • Input connection type
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:SEV 1011 T12
  • Cable type
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:H05VV-F 5 G 2.5 mm2
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:H05VV-F 3G 1.5 mm2
  • Nominal input voltage
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:230-400 V
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:230 V
  • Maximum current
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:16 A
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:10 A
  • Depth
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:833 mm
    • Knürr DIS Rack PDU, Classic, 0U, input SEV1011 T12:933 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 03.600.521.1, 03.703.058.1
18 specifications
Design2 differ
Rack capacityDiffers0U1U
Housing materialDiffersPlastic, Steel, ZincBrass, Plastic, Steel, Zinc
Product colourGreyGrey
PDU typesKnown for oneUnknown — not stated by the sourceSwitched
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers21 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Input connection typeDiffersIEC60309 3ph/N/PE 6hSEV 1011 T12
Features1 differ
Cable length2.5 m2.5 m
Cable typeDiffersH05VV-F 5 G 2.5 mm2H05VV-F 3G 1.5 mm2
Power2 differ
Nominal input voltageDiffers230-400 V230 V
Maximum currentDiffers16 A10 A
Certificates1 differ
CertificationDiffers- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme. - IEC 320.- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme. - VDE GS.
Weight & dimensions1 differ
Width44.4 mm44.4 mm
DepthDiffers833 mm933 mm
Height45.5 mm45.5 mm
Packaging content1 differ
Packaging contentDiffersIEC60309 3ph/N/PE 6h- 1 x socket strip. - 2 x mounting brackets.