  • 12specifications compared
  • 12differ
  • 0identical
  • 9known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14 has 1 U more rack capacity than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (1U vs 0U). The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 22 A more maximum current than the Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14 (32 A vs 10 A). The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 11.6 mm more width than the Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14 (56 mm vs 44.4 mm). Housing material: Brass, Plastic, Steel, Zinc on the Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14, Aluminium on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V. Product colour: Orange, White on the Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14, Black on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V.

  • Rack capacity
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:1U
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:0U
  • Housing material
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:Brass, Plastic, Steel, Zinc
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:Aluminium
  • Product colour
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:Orange, White
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:Black
  • AC outlets quantity
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:8 AC outlet(s)
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:6 AC outlet(s)
  • Power plug
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:C14 coupler
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:IEC 60309
  • AC outlet types
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:Type F
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:C19 coupler
  • Input connection type
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:IEC60320 C14
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:IEC 60309 32A 3P+N+G
  • Nominal input voltage
    • Knürr DIS Rack PDU, Compact, 0U/1U, input IEC 60320 C14:100-240 V
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:230-400 V

Side by side

Differences highlightedShow differences only (off)
Comparison of 03.300.308.1, MPE-3345-002
21 specifications
Design3 differ
Rack capacityDiffers1U0U
Housing materialDiffersBrass, Plastic, Steel, ZincAluminium
Product colourDiffersOrange, WhiteBlack
Ports & interfaces4 differ
AC outlets quantityDiffers8 AC outlet(s)6 AC outlet(s)
Power plugDiffersC14 couplerIEC 60309
AC outlet typesDiffersType FC19 coupler
Input connection typeDiffersIEC60320 C14IEC 60309 32A 3P+N+G
Featuresidentical
Cable lengthKnown for one2.5 mUnknown — not stated by the source
Cable typeKnown for oneH05VV-F 3G 1.5 mm2Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100-240 V230-400 V
Maximum currentDiffers10 A32 A
Certificatesidentical
CertificationKnown for one- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme. - VDE GS.Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers44.4 mm56 mm
DepthDiffers483 mm50 mm
HeightDiffers45.5 mm826.5 mm
Size (imperial)Known for one48.3 cm (19")Unknown — not stated by the source
Packaging contentidentical
Packaging contentKnown for one– 1 x socket strip. – 2 x mounting brackets.Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 85 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source10 - 90%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m