Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko vs Vertiv Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13

Add a product
  • 16specifications compared
  • 8differ
  • 8identical
  • 2known for one product only

Key differences

  • Housing material
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:Brass, Plastic, Steel, Zinc
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:Plastic, Steel, Zinc
  • Product colour
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:Orange, White
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:Black, Grey
  • AC outlets quantity
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:8 AC outlet(s)
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:12 AC outlet(s)
  • Power plug
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:Type F
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:C13 coupler
  • AC outlet types
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:Type F
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:C13 coupler
  • Nominal input voltage
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:100-240 V
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:230 V
  • Maximum current
    • Knürr DIS Rack PDU, Compact, 0U/1U, input Schuko:16 A
    • Knürr DIS Rack PDU, IEC320, 0U/1U, input IEC 60320 C13:10 A

Side by side

Differences highlightedShow differences only (on)
Comparison of 03.300.008.1, 03.600.312.1
18 specifications
Design2 differ
Housing materialDiffersBrass, Plastic, Steel, ZincPlastic, Steel, Zinc
Product colourDiffersOrange, WhiteBlack, Grey
PDU typesKnown for oneUnknown — not stated by the sourceSwitched
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)12 AC outlet(s)
Power plugDiffersType FC13 coupler
AC outlet typesDiffersType FC13 coupler
Input connection typeKnown for oneSchuko CEE7/7Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100-240 V230 V
Maximum currentDiffers16 A10 A
Certificates1 differ
CertificationDiffers- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme. - VDE GS.- CE label in accordance with Low Voltage Directive 2006/95/EC - EMC Directive 2004/108/EC - CB-scheme

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.