Product comparison · 2 power distribution units (pdus)

Origin Storage PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U vs Vertiv Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 6specifications compared
  • 5differ
  • 1identical
  • 21known for one product only

Key differences

  • PDU types
    • PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U:Managed, Metered, Switched
    • Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Monitored
  • AC outlets quantity
    • PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U:8 AC outlet(s)
    • Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
  • AC outlet types
    • PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U:C13 coupler
    • Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U:230 V
    • Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240/346-415 V
  • Maximum current
    • PX4-5297NR-E8-LEG power distribution unit (PDU) 8 AC outlet(s) 0U:32 A
    • Geist MNR5M1R5-12CF13-2PS56B0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:20 A

Side by side

Differences highlightedShow differences only (off)
Comparison of PX4-5297NR-E8-LEG, MNR5M1R5-12CF13-2PS56B0H10-S
27 specifications
Design1 differ
PDU typesDiffersManaged, Metered, SwitchedMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourKnown for oneUnknown — not stated by the sourceBlack
DisplayKnown for oneUnknown — not stated by the sourceLED
Rack mountingKnown for oneNoUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)12 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power2 differ
Nominal input voltageDiffers230 V200-240/346-415 V
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers32 A20 A
Load capacityKnown for oneUnknown — not stated by the source240 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source432 mm
DepthKnown for oneUnknown — not stated by the source305 mm
HeightKnown for oneUnknown — not stated by the source44 mm
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source4.54 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.