Product comparison · 2 power distribution units (pdus)

LogiLink PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black vs Vertiv VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black

Add a product
  • 8specifications compared
  • 6differ
  • 2identical
  • 16known for one product only

Key differences

  • PDU types
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:Monitored
  • Rack capacity
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:16 AC outlet(s)
  • AC outlet types
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:C13 coupler
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:208 V
  • Maximum current
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:10 A
    • VP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black:30 A

Side by side

Differences highlightedShow differences only (off)
Comparison of PDU8A01, VP7811B
24 specifications
Design2 differ
PDU typesDiffersBasicMonitored
Rack capacityDiffers1U2U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourBlackBlack
Housing materialKnown for onePolypropylene (PP)Unknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)16 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceNEMA L6-30P
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceHTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON API, RSTP
Power2 differ
Nominal input voltageDiffers230 V208 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers10 A30 A
Output voltageKnown for oneUnknown — not stated by the source208 V
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensionsidentical
WidthKnown for one482 mmUnknown — not stated by the source
DepthKnown for one45 mmUnknown — not stated by the source
HeightKnown for one45 mmUnknown — not stated by the source