Product comparison · 2 power distribution units (pdus)

Fujitsu S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black vs Fujitsu S26361-F5560-E231 power distribution unit (PDU) 36 AC outlet(s) 0U Black

Add a product
  • 19specifications compared
  • 4differ
  • 15identical
  • 5known for one product only

Key differences

  • Type
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:Single-phase
    • S26361-F5560-E231 power distribution unit (PDU) 36 AC outlet(s) 0U Black:Three-phase
  • AC outlets quantity
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:19 AC outlet(s)
    • S26361-F5560-E231 power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
  • Nominal input voltage
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:200 - 240 V
    • S26361-F5560-E231 power distribution unit (PDU) 36 AC outlet(s) 0U Black:364 - 400 V

Side by side

Differences highlightedShow differences only (off)
Comparison of S26361-F5560-E210, S26361-F5560-E231
24 specifications
Design1 differ
PDU typesMeteredMetered
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers19 AC outlet(s)36 AC outlet(s)
Power plugIEC309IEC309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers17x IEC320 C13 (10A) + 2xIEC320 C19 (16A)6x5(30) IEC320 C13 (10A)+6x1 (6) IEC320 C19 (16A)
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Security algorithms802.1x RADIUS, AES, DES, MD5802.1x RADIUS, AES, DES, MD5
Management featuresidentical
Management protocolsSNMP v1/v2/v3SNMP v1/v2/v3
Supported network protocolsLDAP, TACACS, Radius, KerberosLDAP, TACACS, Radius, Kerberos
Power1 differ
Nominal input voltageDiffers200 - 240 V364 - 400 V
Maximum current16 A16 A
Block 1 output current10 A10 A
Block 2 output current16 A16 A
Maximum powerKnown for oneUnknown — not stated by the source22000 W
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationBV-BG,CB,CEBV-BG,CB,CE
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 85 °CUnknown — not stated by the source
Operating relative humidity (H-H)5 - 95%5 - 95%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.