Product comparison · 2 power distribution units (pdus)

CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 23specifications compared
  • 17differ
  • 6identical
  • 16known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 U more rack capacity than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (2U vs 1U). The CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black has 0.7 m more cable length than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (3.7 m vs 3 m). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 45 A more maximum current than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (60 A vs 15 A). PDU types: Switched on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Type: Single-phase on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black, Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Switched
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Type
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Single-phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
  • Rack capacity
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • AC outlet types
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-15R
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Cable length
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:3.7 m
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
  • Nominal input voltage
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:120 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • AC input frequency
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:50-60 Hz
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:50/60 Hz

Side by side

Differences highlightedShow differences only (on)
Comparison of PDU41021, MN05MDR1-18I6B3-6PS56B0F10-S
39 specifications
Design3 differ
PDU typesDiffersSwitchedMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U2U
Housing materialKnown for oneMetalUnknown — not stated by the source
On/off switchKnown for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlet typesDiffersNEMA 5-15RC13 coupler, C19 coupler
Features1 differ
Cable lengthDiffers3.7 m3 m
Management features2 differ
MonitoringDiffersCurrent, Power, Energy, Temperature, Humidity, Voltage, AlarmCurrent, Power, Voltage
Management platformKnown for oneSNMPUnknown — not stated by the source
Supported network protocolsDiffersIPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog, RADIUS, LDAP, LDAPS, Windows ADDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers120 V200 - 415 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers15 A60 A
Nominal output voltageDiffers100-120 V240 V
Load capacityKnown for oneUnknown — not stated by the source34500 VA
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersUL, Federal Communications Commission (FCC), RoHSCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one32 - 140 °FUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3500 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 14999 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm435 mm
DepthDiffers215 mm740 mm
HeightDiffers44 mm88 mm
WeightDiffers3.81 kg11.3 kg
Packaging dataidentical
Package weightKnown for one5.53 kgUnknown — not stated by the source
Package widthKnown for one552.5 mmUnknown — not stated by the source
Package depthKnown for one406.4 mmUnknown — not stated by the source
Package heightKnown for one127 mmUnknown — not stated by the source