Product comparison · 2 power distribution units (pdus)

CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black vs Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black

Add a product
  • 20specifications compared
  • 16differ
  • 4identical
  • 19known for one product only

Key differences

The CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1.7 m more cable length than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (3.7 m vs 2 m). The Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black has 110 V more nominal input voltage than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (230 V vs 120 V). The Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black has 1 A more maximum current than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (16 A vs 15 A). PDU types: Switched on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black, Basic on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black. AC outlets quantity: 16 AC outlet(s) on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black, 4 AC outlet(s) on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black.

  • PDU types
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Switched
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Basic
  • AC outlets quantity
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
  • Power plug
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-15P
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:C14 coupler
  • AC outlet types
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-15R
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Type F
  • Cable length
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:3.7 m
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:2 m
  • Nominal input voltage
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:120 V
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V
  • Maximum current
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:15 A
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:16 A
  • Nominal output voltage
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:100-120 V
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V

Side by side

Differences highlightedShow differences only (on)
Comparison of PDU41021, LVR-2MSCH-SCH-C13-4
39 specifications
Design1 differ
PDU typesDiffersSwitchedBasic
Housing materialKnown for oneMetalUnknown — not stated by the source
DisplayKnown for oneLCDUnknown — not stated by the source
On/off switchKnown for oneYesUnknown — not stated by the source
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers16 AC outlet(s)4 AC outlet(s)
Power plugDiffersNEMA 5-15PC14 coupler
AC outlet typesDiffersNEMA 5-15RType F
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Features1 differ
Daisy chainKnown for oneYesUnknown — not stated by the source
Reset buttonKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers3.7 m2 m
LED indicatorsKnown for oneUnknown — not stated by the sourcePower
Management featuresidentical
MonitoringKnown for oneCurrent, Power, Energy, Temperature, Humidity, Voltage, AlarmUnknown — not stated by the source
Management platformKnown for oneSNMPUnknown — not stated by the source
Supported network protocolsKnown for oneIPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog, RADIUS, LDAP, LDAPS, Windows ADUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers120 V230 V
AC input frequencyKnown for one50-60 HzUnknown — not stated by the source
Maximum currentDiffers15 A16 A
Nominal output voltageDiffers100-120 V230 V
Certificatesidentical
Compliance certificatesKnown for oneUL, Federal Communications Commission (FCC), RoHSUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one32 - 140 °FUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3500 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 14999 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm500 mm
DepthDiffers215 mm80 mm
HeightDiffers44 mm60 mm
WeightDiffers3.81 kg1.1 kg
Size (imperial)Known for oneUnknown — not stated by the source25.4 cm (10")
Packaging data4 differ
Package weightDiffers5.53 kg1.2 kg
Package widthDiffers552.5 mm500 mm
Package depthDiffers406.4 mm80 mm
Package heightDiffers127 mm60 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons