Product comparison · 2 power distribution units (pdus)

CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black vs Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12

Add a product
  • 7specifications compared
  • 7differ
  • 0identical
  • 23known for one product only

Key differences

  • PDU types
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:Monitored
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:Metered
  • Rack capacity
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:2U
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:0U/1U
  • Mounting
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:Horizontal
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:Horizontal/Vertical
  • Product colour
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:Black
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:Black, Grey
  • AC outlets quantity
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:16 AC outlet(s)
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:5 AC outlet(s)
  • Nominal input voltage
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:200 - 240 V
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:230 V
  • Maximum current
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:24 A
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input SEV1011 T12:10 A

Side by side

Differences highlightedShow differences only (on)
Comparison of PDU31008, 037060051
30 specifications
Design4 differ
PDU typesDiffersMonitoredMetered
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers2U0U/1U
MountingDiffersHorizontalHorizontal/Vertical
Housing materialKnown for oneSteelUnknown — not stated by the source
Product colourDiffersBlackBlack, Grey
Ports & interfaces1 differ
AC outlets quantityDiffers16 AC outlet(s)5 AC outlet(s)
Power plugKnown for oneNEMA L6-30PUnknown — not stated by the source
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Input connection typeKnown for oneUnknown — not stated by the sourceSEV 1011 T13
Featuresidentical
Reset buttonKnown for oneYesUnknown — not stated by the source
LED indicatorsKnown for oneLink, StatusUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers200 - 240 V230 V
AC input frequencyKnown for one50 / 60 HzUnknown — not stated by the source
Maximum currentDiffers24 A10 A
Nominal output voltageKnown for one200 - 240 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneFCC Class A, UL60950Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one32 - 113 °FUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 55 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one433 mmUnknown — not stated by the source
DepthKnown for one112 mmUnknown — not stated by the source
HeightKnown for one88 mmUnknown — not stated by the source
WeightKnown for one4.1 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one500 gUnknown — not stated by the source
Package widthKnown for one250 mmUnknown — not stated by the source
Package depthKnown for one150 mmUnknown — not stated by the source
Package heightKnown for one6100 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons