Product comparison · 2 power distribution units (pdus)

CyberPower MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black vs Vertiv MPE Rack PDU, elementary, 0U, input Hardwired

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 8known for one product only

Key differences

  • Rack capacity
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:1U
    • MPE Rack PDU, elementary, 0U, input Hardwired:0U
  • Housing material
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:Steel
    • MPE Rack PDU, elementary, 0U, input Hardwired:Aluminium
  • AC outlets quantity
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:5 AC outlet(s)
    • MPE Rack PDU, elementary, 0U, input Hardwired:42 AC outlet(s)
  • AC outlet types
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:NEMA 5–20R
    • MPE Rack PDU, elementary, 0U, input Hardwired:C13 coupler, C19 coupler
  • Nominal input voltage
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:100 - 120 V
    • MPE Rack PDU, elementary, 0U, input Hardwired:230 V
  • Maximum current
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:30 A
    • MPE Rack PDU, elementary, 0U, input Hardwired:32 A
  • Operating temperature (T-T)
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:0 - 40 °C
    • MPE Rack PDU, elementary, 0U, input Hardwired:5 - 60 °C
  • Operating relative humidity (H-H)
    • MBP30A5 power distribution unit (PDU) 5 AC outlet(s) 1U Black:0 - 90%
    • MPE Rack PDU, elementary, 0U, input Hardwired:10 - 90%

Side by side

Differences highlightedShow differences only (off)
Comparison of MBP30A5, MPE-1260
20 specifications
Design2 differ
Rack capacityDiffers1U0U
Housing materialDiffersSteelAluminium
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers5 AC outlet(s)42 AC outlet(s)
Power plugKnown for oneNEMA L5-20PUnknown — not stated by the source
AC outlet typesDiffersNEMA 5–20RC13 coupler, C19 coupler
Featuresidentical
Cable lengthKnown for one1.82 mUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100 - 120 V230 V
Maximum currentDiffers30 A32 A
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUL60950_1, cULUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C5 - 60 °C
Operating relative humidity (H-H)Differs0 - 90%10 - 90%
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 85 °C
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions3 differ
WidthDiffers431.8 mm56 mm
DepthDiffers76.2 mm50 mm
HeightDiffers50.8 mm1736.5 mm
WeightKnown for one2.7 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.