Product comparison · 2 power distribution units (pdus)

ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software vs Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black

Add a product
  • 15specifications compared
  • 10differ
  • 5identical
  • 15known for one product only

Key differences

The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 120 - 240 V more nominal input voltage than the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software (220 - 240 V vs 100 - 240 V). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 300 mm more width than the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software (510 mm vs 210 mm). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 77.6 mm more depth than the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software (510 mm vs 432.4 mm). PDU types: Switched on the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software, Basic on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black. AC outlets quantity: 8 AC outlet(s) on the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software, 24 AC outlet(s) on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black.

  • PDU types
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:Switched
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:Basic
  • AC outlets quantity
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:8 AC outlet(s)
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:24 AC outlet(s)
  • Monitoring
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:Current, Voltage
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:Current, Power, Voltage
  • Nominal input voltage
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:220 - 240 V
  • AC input frequency
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:50-60 Hz
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:50 - 60 Hz
  • Output voltage
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:230 V
  • Width
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:210 mm
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:510 mm
  • Depth
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:432.4 mm
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:510 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PG6308G, VP0G9000
30 specifications
Design1 differ
PDU typesDiffersSwitchedBasic
Rack capacityKnown for one1UUnknown — not stated by the source
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces1 differ
AC outlets quantityDiffers8 AC outlet(s)24 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Featuresidentical
Reset buttonKnown for oneYesUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable length3 m3 m
Management features1 differ
MonitoringDiffersCurrent, VoltageCurrent, Power, Voltage
Power3 differ
Nominal input voltageDiffers100 - 240 V220 - 240 V
AC input frequencyDiffers50-60 Hz50 - 60 Hz
Maximum current32 A32 A
Output voltageDiffers100 - 240 V230 V
Load capacityKnown for one7680 VAUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source7300 W
Certificatesidentical
CertificationKnown for oneCE, UKCAUnknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers210 mm510 mm
DepthDiffers432.4 mm510 mm
HeightDiffers44 mm1683 mm
WeightDiffers4.09 kg6.35 kg
Logistics dataidentical
Country of originKnown for oneTaiwanUnknown — not stated by the source