Product comparison · 2 power distribution units (pdus)

ATEN PE9330 power distribution unit (PDU) 30 AC outlet(s) Black vs Lenovo Enterprise C19 PDU

Add a product
  • 9specifications compared
  • 9differ
  • 0identical
  • 13known for one product only

Key differences

  • PDU types
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:Monitored
    • Enterprise C19 PDU:Basic
  • AC outlets quantity
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:30 AC outlet(s)
    • Enterprise C19 PDU:6 AC outlet(s)
  • AC outlet types
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:C13 coupler, C19 coupler
    • Enterprise C19 PDU:C19 coupler
  • Nominal input voltage
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:100-240 V
    • Enterprise C19 PDU:200 - 240 V
  • Maximum current
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:30 A
    • Enterprise C19 PDU:60 A
  • Width
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:1775 mm
    • Enterprise C19 PDU:439 mm
  • Depth
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:66 mm
    • Enterprise C19 PDU:213 mm
  • Height
    • PE9330 power distribution unit (PDU) 30 AC outlet(s) Black:44 mm
    • Enterprise C19 PDU:43.9 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE9330, Enterprise C19 PDU
22 specifications
Design1 differ
PDU typesDiffersMonitoredBasic
Product colourKnown for oneBlackUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)6 AC outlet(s)
Power plugKnown for oneNEMA L5-30PUnknown — not stated by the source
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
Output connectionsKnown for oneUnknown — not stated by the source6 x IEC 320 EN 60320 C19
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one1.6 mUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneCurrentUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100-240 V200 - 240 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers30 A60 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one6240 VAUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers1775 mm439 mm
DepthDiffers66 mm213 mm
HeightDiffers44 mm43.9 mm
WeightDiffers6.4 kg9.6 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.