Product comparison · 2 power distribution units (pdus)

ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU vs Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 34known for one product only

Key differences

The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1.4 m more cable length than the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU (3 m vs 1.6 m). The ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has 2 A more maximum current than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (32 A vs 30 A). The ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has 1,660 VA more load capacity than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (7360 VA vs 5700 VA). PDU types: Metered on the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU, Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black. Mounting: Horizontal/Vertical on the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU, Horizontal on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:Metered
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
  • Mounting
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:Horizontal/Vertical
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:24 AC outlet(s)
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:IEC 60309
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA L14-30P
  • AC outlet types
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:C13 coupler, C19 coupler
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-20R, C13 coupler
  • Cable length
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:1.6 m
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:3 m
  • AC input frequency
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:50 - 60 Hz
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:50/60 Hz
  • Maximum current
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:32 A
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:30 A

Side by side

Differences highlightedShow differences only (off)
Comparison of PE8324G2-AT, MN00X1R1-16MCQ9-3TL14A0A10-S
51 specifications
Design2 differ
PDU typesDiffersMeteredBasic
Form factorKnown for oneRackmountUnknown — not stated by the source
Rack capacity1U1U
MountingDiffersHorizontal/VerticalHorizontal
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC 60309NEMA L14-30P
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-20R, C13 coupler
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
I/O portsKnown for oneSensor PortUnknown — not stated by the source
Features1 differ
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers1.6 m3 m
Management featuresidentical
MonitoringKnown for oneCurrent, Humidity, Power, Temperature, VoltageUnknown — not stated by the source
Outlet controlKnown for oneRecycle, Turn off, Turn onUnknown — not stated by the source
Supported network protocolsKnown for oneTCP / IP, UDP, HTTP, HTTPS, SSL, DHCP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2 and V3Unknown — not stated by the source
Power4 differ
Nominal input voltage100 - 240 V100 - 240 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers32 A30 A
Block 1 output currentKnown for one16 AUnknown — not stated by the source
Block 2 output currentKnown for one16 AUnknown — not stated by the source
Nominal output voltageDiffers100 - 240 V208 V
Load capacityDiffers7360 VA5700 VA
Maximum powerKnown for oneUnknown — not stated by the source5700 W
Certificatesidentical
CertificationKnown for oneCEUnknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceTrade Agreements Act (TAA), UL, cUL, RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers66 mm50.8 mm
DepthDiffers1775 mm50.8 mm
HeightDiffers44 mm1682.7 mm
WeightDiffers6.33 kg6.8 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source
Resource CDKnown for oneYesUnknown — not stated by the source
Packaging contentKnown for one1 x Power Distribution Unit 1 x mounting kit 1 x CD-ROM 1 x user instructionsUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one9.37 kgUnknown — not stated by the source
Package widthKnown for one229 mmUnknown — not stated by the source
Package depthKnown for one1865 mmUnknown — not stated by the source
Package heightKnown for one179 mmUnknown — not stated by the source
Package volumeKnown for one76455.49 cm³Unknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneTaiwanUnknown — not stated by the source
Master (outer) case net weightKnown for one6.72 kgUnknown — not stated by the source
Master (outer) case widthKnown for one229 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one1865 mmUnknown — not stated by the source
Master (outer) case heightKnown for one179 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one9.37 kgUnknown — not stated by the source
Master (outer) case volumeKnown for one76455.49 cm³Unknown — not stated by the source
Products per master (outer) caseKnown for one1 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.