Product comparison · 2 power distribution units (pdus)

ATEN 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software vs CyberPower CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black

Add a product
  • 19specifications compared
  • 18differ
  • 1identical
  • 8known for one product only

Key differences

  • PDU types
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Metered
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:Basic
  • Rack capacity
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:0U
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:16 AC outlet(s)
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
  • Power plug
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:C20 coupler
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:NEMA 5–15P
  • AC outlet types
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:NEMA 5–15R
  • Cable length
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:1.6 m
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:4.57 m
  • Nominal input voltage
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:100-240 V
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:120 V
  • AC input frequency
    • 16A 16 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:60 Hz

Side by side

Differences highlightedShow differences only (off)
Comparison of PE8216G, CPS-1215RM
27 specifications
Design2 differ
PDU typesDiffersMeteredBasic
Rack capacityDiffers0U1U
Housing materialKnown for oneMetalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers16 AC outlet(s)10 AC outlet(s)
Power plugDiffersC20 couplerNEMA 5–15P
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
Output connectionsKnown for one14 x IEC320 C13 & 2 x IEC320 C19Unknown — not stated by the source
Features1 differ
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers1.6 m4.57 m
Management featuresidentical
Management platformKnown for oneSNMP v1/v2/v3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers100-240 V120 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentDiffers16 A15 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityDiffers3680 VA1800 VA
Certificates1 differ
CertificationDiffersTUV-CB, CE-LVD, CEUL
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C-20 - 46 °C
Storage temperature (T-T)Differs-20 - 60 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 80%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Weight & dimensions4 differ
WidthDiffers66 mm438.1 mm
DepthDiffers1325 mm120.7 mm
HeightDiffers44 mm44.5 mm
WeightDiffers3.9 kg2.27 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons