The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 18 A more maximum current than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (30 A vs 12 A). The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 3,300 VA more load capacity than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (5700 VA vs 2400 VA). The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 4,260 W more maximum power than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (5700 W vs 1440 W). PDU types: Metered, Switched on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black, Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black. AC outlets quantity: 8 AC outlet(s) on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black, 16 AC outlet(s) on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
  • AC outlets quantity
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20P
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA L14-30P
  • AC outlet types
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5–20R
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-20R, C13 coupler
  • Maximum current
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:12 A
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:30 A
  • Nominal output voltage
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:208 V
  • Load capacity
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:2400 VA
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 VA
  • Maximum power
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1440 W
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 W

Side by side

Differences highlightedShow differences only (off)
Comparison of PE8208AV-ATB-G, MN00X1R1-16MCQ9-3TL14A0A10-S
35 specifications
Design1 differ
PDU typesDiffersMetered, SwitchedBasic
Rack capacity1U1U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)16 AC outlet(s)
Power plugDiffersNEMA 5-20PNEMA L14-30P
AC outlet typesDiffersNEMA 5–20RNEMA 5-20R, C13 coupler
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Featuresidentical
Cable length3 m3 m
Security algorithmsKnown for one128-bit SSLUnknown — not stated by the source
Password protectionKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Firmware upgradeableKnown for oneYesUnknown — not stated by the source
Management protocolsKnown for oneSNMP Manager V3Unknown — not stated by the source
Supported network protocolsKnown for oneTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, TelnetUnknown — not stated by the source
Power4 differ
Nominal input voltage100 - 240 V100 - 240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers12 A30 A
Nominal output voltageDiffers100 - 240 V208 V
Load capacityDiffers2400 VA5700 VA
Maximum powerDiffers1440 W5700 W
Circuit breakerKnown for oneYesUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersFederal Communications Commission (FCC)Trade Agreements Act (TAA), UL, cUL, RoHS
Sustainabilityidentical
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers220.4 mm50.8 mm
DepthDiffers432.4 mm50.8 mm
HeightDiffers44 mm1682.7 mm
WeightDiffers2.84 kg6.8 kg
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.