Product comparison · 2 power distribution units (pdus)

ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) vs Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309

Add a product
  • 11specifications compared
  • 10differ
  • 1identical
  • 17known for one product only

Key differences

  • AC outlets quantity
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 AC outlet(s)
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:24 AC outlet(s)
  • Nominal input voltage
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):100-240 V
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:230 V
  • Maximum current
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 A
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:32 A
  • Operating temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 40 °C
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:0 - 60 °C
  • Storage temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):-20 - 60 °C
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:-25 - 85 °C
  • Operating relative humidity (H-H)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 80%
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:5 - 95%
  • Width
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):66 mm
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:56 mm
  • Depth
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):1324.8 mm
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:50 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE6216, MPHR1143
28 specifications
Designidentical
PDU typesKnown for oneUnknown — not stated by the sourceMetered, Switched
Rack capacityKnown for oneUnknown — not stated by the source0U
Product colourKnown for oneUnknown — not stated by the sourceBlack
On/off switchKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsKnown for oneUnknown — not stated by the source18 x C13 & 6 x C19
Input connection typeKnown for oneIEC 60320 C20Unknown — not stated by the source
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceWeb, CLI, SNMP, SSH, Telnet
Power2 differ
Nominal input voltageDiffers100-240 V230 V
Maximum currentDiffers16 A32 A
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Nominal output voltageKnown for one110-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum powerKnown for one100 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationDiffersCE C-Tick TUV-CB GOSTUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTA
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Differs-20 - 60 °C-25 - 85 °C
Operating relative humidity (H-H)Differs0 - 80%5 - 95%
Weight & dimensions3 differ
WidthDiffers66 mm56 mm
DepthDiffers1324.8 mm50 mm
HeightDiffers44 mm1736.5 mm
WeightKnown for one3.73 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons