Product comparison · 2 power distribution units (pdus)

ATEN PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black vs Techly IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black

Add a product
  • 13specifications compared
  • 11differ
  • 2identical
  • 19known for one product only

Key differences

  • AC outlets quantity
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:9 AC outlet(s)
  • Nominal input voltage
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:100-120 V
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:100 - 280 V
  • AC input frequency
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:50-60 Hz
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:40/70 Hz
  • Maximum current
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:15 A
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:16 A
  • Operating temperature (T-T)
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:0 - 45 °C
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:0 - 40 °F
  • Operating relative humidity (H-H)
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:0 - 80%
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:0 - 90%
  • Width
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:432.4 mm
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:448 mm
  • Depth
    • PE6108AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:267.3 mm
    • IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black:44 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6108AV, IUPS-SRA16-A3
32 specifications
Designidentical
On/off switchKnown for oneYesUnknown — not stated by the source
PDU typesKnown for oneUnknown — not stated by the sourceBasic
MountingKnown for oneUnknown — not stated by the sourceHorizontal/Vertical
Housing materialKnown for oneUnknown — not stated by the sourceMetal, Plastic
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
Power plugKnown for oneNEMA 5–15PUnknown — not stated by the source
AC outlet typesDiffersNEMA 5–15RC13 coupler, C19 coupler, C20 coupler
Serial ports quantityKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for one3 mUnknown — not stated by the source
Security algorithmsKnown for one128-bit SSL, 802.1x RADIUSUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneCurrent, Humidity, Power, Temperature, VoltageUnknown — not stated by the source
Supported network protocolsKnown for oneTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3, TelnetUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers100-120 V100 - 280 V
AC input frequencyDiffers50-60 Hz40/70 Hz
Maximum currentDiffers15 A16 A
Nominal output voltageKnown for one100-120 VUnknown — not stated by the source
Load capacityKnown for one1800 VAUnknown — not stated by the source
Certificatesidentical
CertificationKnown for onePSE, FCC, J55032Unknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 40 °F
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 80%0 - 90%
Weight & dimensions4 differ
WidthDiffers432.4 mm448 mm
DepthDiffers267.3 mm44 mm
HeightDiffers44 mm10 mm
WeightDiffers3.7 kg3.8 kg
Size (imperial)Known for one48.3 cm (19")Unknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneAC, LAN (RJ-45)Unknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.