Product comparison · 2 power distribution units (pdus)

ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black vs Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V

Add a product
  • 11specifications compared
  • 8differ
  • 3identical
  • 21known for one product only

Key differences

The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 16 A more maximum current than the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black (32 A vs 16 A). The ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black has 852 mm more depth than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (902 mm vs 50 mm). The Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V has 778.5 mm more height than the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black (826.5 mm vs 48 mm). AC outlets quantity: 21 AC outlet(s) on the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black, 6 AC outlet(s) on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V. AC outlet types: C13 coupler, C19 coupler on the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black, C19 coupler on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V.

  • AC outlets quantity
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:21 AC outlet(s)
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:6 AC outlet(s)
  • AC outlet types
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:C13 coupler, C19 coupler
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:C19 coupler
  • Nominal input voltage
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:100-240 V
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:16 A
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:32 A
  • Operating temperature (T-T)
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:0 - 40 °C
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:5 - 60 °C
  • Operating relative humidity (H-H)
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:0 - 80%
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:10 - 90%
  • Depth
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:902 mm
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:50 mm
  • Height
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:48 mm
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:826.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE5221T, MPE-3345-002
32 specifications
Designidentical
PDU typesKnown for oneMeteredUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacity0U0U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Ports & interfaces2 differ
AC outlets quantityDiffers21 AC outlet(s)6 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32A 3P+N+G
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Supported network protocolsKnown for oneTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, SNMP V1,V2&V3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100-240 V230-400 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneCE, FCC, J55022 CE-LVD, PSEUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C5 - 60 °C
Operating relative humidity (H-H)Differs0 - 80%10 - 90%
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 85 °C
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions2 differ
Width56 mm56 mm
DepthDiffers902 mm50 mm
HeightDiffers48 mm826.5 mm
WeightKnown for one2.34 kgUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source