Product comparison · 2 power distribution units (pdus)

ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black vs Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black

Add a product
  • 11specifications compared
  • 9differ
  • 2identical
  • 20known for one product only

Key differences

The Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black has 1 U more rack capacity than the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black (1U vs 0U). The Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black has 1 m more cable length than the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black (4 m vs 3 m). The Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black has 16 A more maximum current than the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black (32 A vs 16 A). AC outlets quantity: 21 AC outlet(s) on the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black, 15 AC outlet(s) on the Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black. Nominal input voltage: 100-240 V on the ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black, 230-400 V on the Vertiv Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black.

  • Rack capacity
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:0U
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:21 AC outlet(s)
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:15 AC outlet(s)
  • Cable length
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:3 m
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:4 m
  • Nominal input voltage
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:100-240 V
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:230-400 V
  • Maximum current
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:16 A
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:32 A
  • Width
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:56 mm
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:84 mm
  • Depth
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:902 mm
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:740 mm
  • Height
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:48 mm
    • Knürr 03.630.815.1 power distribution unit (PDU) 15 AC outlet(s) 1U Black:60 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE5221T, 03.630.815.1
31 specifications
Design1 differ
PDU typesKnown for oneMeteredUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceSteel, Zinc
Ports & interfaces1 differ
AC outlets quantityDiffers21 AC outlet(s)15 AC outlet(s)
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Features1 differ
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers3 m4 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 5 G 4 mm2
Management featuresidentical
Supported network protocolsKnown for oneTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, SNMP V1,V2&V3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100-240 V230-400 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersCE, FCC, J55022 CE-LVD, PSE- CE Label in accordance with low voltage directive 2006/95/EEC EMC Directive 2006/108/EEC - Innova GS - CSA NRTL/C
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm84 mm
DepthDiffers902 mm740 mm
HeightDiffers48 mm60 mm
WeightKnown for one2.34 kgUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging contentKnown for oneUnknown — not stated by the source1 socket strip (PDU) 2 mounting brackets 1 19” mounting bracket (additional with 19 installation option) Operating instructions

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.