Product comparison · 2 power distribution units (pdus)

ATEN PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black vs Vertiv Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 24known for one product only

Key differences

  • Rack capacity
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:0U
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:1U
  • Product colour
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:Black
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:Grey
  • AC outlets quantity
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:21 AC outlet(s)
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:6 AC outlet(s)
  • Nominal input voltage
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:100-240 V
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:230 V
  • Width
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:56 mm
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:44.4 mm
  • Depth
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:902 mm
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:483 mm
  • Height
    • PE5221T power distribution unit (PDU) 21 AC outlet(s) 0U Black:48 mm
    • Knürr DIS Rack PDU, Safety Basic, 0U/1U, input Schuko:45.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE5221T, 03.416.006.1
33 specifications
Design2 differ
PDU typesKnown for oneMeteredUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourDiffersBlackGrey
Housing materialKnown for oneUnknown — not stated by the sourceBrass, Plastic, Steel, Zinc
Ports & interfaces1 differ
AC outlets quantityDiffers21 AC outlet(s)6 AC outlet(s)
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneUnknown — not stated by the sourceSchuko CEE7/7
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one3 mUnknown — not stated by the source
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 3G 1.5 mm2
Management featuresidentical
Supported network protocolsKnown for oneTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, SNMP V1,V2&V3Unknown — not stated by the source
Power1 differ
Nominal input voltageDiffers100-240 V230 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum current16 A16 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersCE, FCC, J55022 CE-LVD, PSE- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme.
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm44.4 mm
DepthDiffers902 mm483 mm
HeightDiffers48 mm45.5 mm
WeightKnown for one2.34 kgUnknown — not stated by the source
Size (imperial)Known for oneUnknown — not stated by the source48.3 cm (19")
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging contentKnown for oneUnknown — not stated by the source– 1 x socket strip. – 2 x mounting bracket

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons