Product comparison · 2 power distribution units (pdus)

ATEN 1U Basic PDU with Surge Protection vs ATEN 20A/16A 30-Outlet 3-Phase Metered eco PDU

Add a product
  • 20specifications compared
  • 14differ
  • 6identical
  • 34known for one product only

Key differences

  • PDU types
    • 1U Basic PDU with Surge Protection:Basic
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:Metered
  • Rack capacity
    • 1U Basic PDU with Surge Protection:1U
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:0U
  • AC outlets quantity
    • 1U Basic PDU with Surge Protection:18 AC outlet(s)
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:30 AC outlet(s)
  • Power plug
    • 1U Basic PDU with Surge Protection:NEMA L6-20P
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:IEC309
  • AC outlet types
    • 1U Basic PDU with Surge Protection:C13 coupler
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:C13 coupler, C19 coupler
  • Nominal input voltage
    • 1U Basic PDU with Surge Protection:100 - 240 V
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:400 V
  • Maximum current
    • 1U Basic PDU with Surge Protection:20 A
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:16 A
  • Load capacity
    • 1U Basic PDU with Surge Protection:4800 VA
    • 20A/16A 30-Outlet 3-Phase Metered eco PDU:11084 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of PE0218SB, PG95230G
54 specifications
Design2 differ
PDU typesDiffersBasicMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers1U0U
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)30 AC outlet(s)
Power plugDiffersNEMA L6-20PIEC309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source4
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable length3 m3 m
Security algorithmsKnown for oneUnknown — not stated by the sourceTLS
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Humidity, Power, Temperature, Voltage
Management protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus
Supported network protocolsKnown for oneUnknown — not stated by the sourceIPv6, SMS
Power3 differ
Nominal input voltageDiffers100 - 240 V400 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers20 A16 A
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Load capacityDiffers4800 VA11084 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Circuit breakerKnown for oneUnknown — not stated by the sourceNo
Block 1 output currentKnown for one20 AUnknown — not stated by the source
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersFederal Communications Commission (FCC)CE
Sustainabilityidentical
Sustainability complianceYesYes
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers44.4 mm56 mm
DepthDiffers482 mm1790 mm
HeightDiffers88.5 mm68 mm
WeightDiffers1.26 kg7.34 kg
Packaging contentidentical
ManualYesYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneACUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.72 kg
Package widthKnown for oneUnknown — not stated by the source229 mm
Package depthKnown for oneUnknown — not stated by the source1945 mm
Package heightKnown for oneUnknown — not stated by the source179 mm
Package volumeKnown for oneUnknown — not stated by the source79853.5074 cm³
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source7.5 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source229 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source1945 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source179 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source10.1 kg
Master (outer) case volumeKnown for oneUnknown — not stated by the source79853.5074 cm³

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.