Product comparison · 2 power distribution units (pdus)

APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black vs Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V

Add a product
  • 12specifications compared
  • 10differ
  • 2identical
  • 18known for one product only

Key differences

The APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black has 93 A more maximum current than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (125 A vs 32 A). The APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black has 376 mm more width than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (432 mm vs 56 mm). The APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black has 375 mm more depth than the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V (425 mm vs 50 mm). AC outlets quantity: 13 AC outlet(s) on the APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black, 6 AC outlet(s) on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V. AC outlet types: C13 coupler, C19 coupler on the APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black, C19 coupler on the Vertiv MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V.

  • AC outlets quantity
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:13 AC outlet(s)
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:6 AC outlet(s)
  • AC outlet types
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:C13 coupler, C19 coupler
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:C19 coupler
  • Nominal input voltage
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:220 V
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:125 A
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:32 A
  • Operating temperature (T-T)
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:-5 - 45 °C
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:5 - 60 °C
  • Storage temperature (T-T)
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:-25 - 65 °C
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:-20 - 85 °C
  • Operating relative humidity (H-H)
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:5 - 95%
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:10 - 90%
  • Width
    • SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black:432 mm
    • MPE Rack PDU, elementary, 0U, input IEC 60309 230/400V:56 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SPD20KCBL, MPE-3345-002
30 specifications
Designidentical
PDU typesKnown for oneMeteredUnknown — not stated by the source
Product colourBlackBlack
Rack capacityKnown for oneUnknown — not stated by the source0U
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Ports & interfaces2 differ
AC outlets quantityDiffers13 AC outlet(s)6 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32A 3P+N+G
Power2 differ
Nominal input voltageDiffers220 V230-400 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers125 A32 A
Nominal output voltageKnown for one220 VUnknown — not stated by the source
Load capacityKnown for one20000 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one125 AUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 45 °C5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 85 °C
Operating relative humidity (H-H)Differs5 - 95%10 - 90%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers432 mm56 mm
DepthDiffers425 mm50 mm
HeightDiffers176 mm826.5 mm
WeightKnown for one13.9 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one19.5 kgUnknown — not stated by the source
Package widthKnown for one596 mmUnknown — not stated by the source
Package depthKnown for one494 mmUnknown — not stated by the source
Package heightKnown for one319 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.