Product comparison · 2 power distribution units (pdus)

APC SBPSU10K30FC1M1-WP power distribution unit (PDU) Black vs Vertiv Liebert MPH, Managed Rack PDU

Add a product
  • 10specifications compared
  • 8differ
  • 2identical
  • 11known for one product only

Key differences

  • Load capacity
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:30000 VA
    • Liebert MPH, Managed Rack PDU:12800 VA
  • Maximum input current per phase
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:92 A
    • Liebert MPH, Managed Rack PDU:32 A
  • Maximum total current draw per phase
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:83.3 A
    • Liebert MPH, Managed Rack PDU:32 A
  • Operating temperature (T-T)
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:0 - 40 °C
    • Liebert MPH, Managed Rack PDU:0 - 55 °C
  • Storage temperature (T-T)
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:0 - 40 °C
    • Liebert MPH, Managed Rack PDU:-20 - 60 °C
  • Width
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:949 mm
    • Liebert MPH, Managed Rack PDU:50 mm
  • Depth
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:197 mm
    • Liebert MPH, Managed Rack PDU:80 mm
  • Height
    • SBPSU10K30FC1M1-WP power distribution unit (PDU) Black:749 mm
    • Liebert MPH, Managed Rack PDU:1730 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of SBPSU10K30FC1M1-WP, Liebert MPH, Managed Rack PDU
21 specifications
Power3 differ
Nominal input voltageKnown for one208 VUnknown — not stated by the source
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Load capacityDiffers30000 VA12800 VA
Maximum input current per phaseDiffers92 A32 A
Maximum total current draw per phaseDiffers83.3 A32 A
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 55 °C
Storage temperature (T-T)Differs0 - 40 °C-20 - 60 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers949 mm50 mm
DepthDiffers197 mm80 mm
HeightDiffers749 mm1730 mm
WeightKnown for one54.5 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one59.1 kgUnknown — not stated by the source
Package widthKnown for one1051 mmUnknown — not stated by the source
Package depthKnown for one228 mmUnknown — not stated by the source
Package heightKnown for one927 mmUnknown — not stated by the source
Ports & interfacesidentical
Input connection typeKnown for oneUnknown — not stated by the sourceIEC-309
Output connectionsKnown for oneUnknown — not stated by the source27 x IEC-C13

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons