Key differences

  • PDU types
    • Rack-mount Transfer Switches:Switched
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:Basic
  • AC outlets quantity
    • Rack-mount Transfer Switches:1 AC outlet(s)
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
  • Cable length
    • Rack-mount Transfer Switches:0.91 m
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:4.57 m
  • Nominal input voltage
    • Rack-mount Transfer Switches:208 V
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:120 V
  • AC input frequency
    • Rack-mount Transfer Switches:50 - 60 Hz
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:60 Hz
  • Maximum current
    • Rack-mount Transfer Switches:16 A
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Load capacity
    • Rack-mount Transfer Switches:3840 VA
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:1800 VA
  • Operating temperature (T-T)
    • Rack-mount Transfer Switches:-5 - 45 °C
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:-20 - 46 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of Rack-mount Transfer Switches, CPS-1215RM
33 specifications
Design1 differ
PDU typesDiffersSwitchedBasic
MountingKnown for oneHorizontalUnknown — not stated by the source
Product colourBlackBlack
Rack capacityKnown for oneUnknown — not stated by the source1U
Ports & interfaces1 differ
AC outlets quantityDiffers1 AC outlet(s)10 AC outlet(s)
Input connection typeKnown for oneIEC 309 16A 2P+EUnknown — not stated by the source
Output connectionsKnown for one(1) IEC 309 16A (2P+E)Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5–15P
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–15R
Features1 differ
Cable lengthDiffers0.91 m4.57 m
Power4 differ
Nominal input voltageDiffers208 V120 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentDiffers16 A15 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers3840 VA1800 VA
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersC-tick, CE, EN 55022 Class A, EN 55024, GOST, TUV, VCCI Class A, REACHUL
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 45 °C-20 - 46 °C
Storage temperature (T-T)Differs-25 - 65 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Non-operating altitude0 - 15000 m0 - 15000 m
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions4 differ
WidthDiffers432 mm438.1 mm
DepthDiffers236 mm120.7 mm
HeightDiffers44 mm44.5 mm
WeightDiffers4.21 kg2.27 kg
Packaging dataidentical
Package weightKnown for one5.95 kgUnknown — not stated by the source
Package widthKnown for one600 mmUnknown — not stated by the source
Package depthKnown for one349 mmUnknown — not stated by the source