  • Maximum input current per phase
    • Rack ATS, 2U, 208V:30 A
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:16 A
  • Operating temperature (T-T)
    • Rack ATS, 2U, 208V:-5 - 45 °C
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:10 - 50 °C
  • Storage temperature (T-T)
    • Rack ATS, 2U, 208V:-25 - 65 °C
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:-40 - 65 °C
  • Operating relative humidity (H-H)
    • Rack ATS, 2U, 208V:5 - 95%
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:20 - 80%
  • Width
    • Rack ATS, 2U, 208V:432 mm
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:5.6 mm
  • Depth
    • Rack ATS, 2U, 208V:236 mm
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:167.6 mm
  • Height
    • Rack ATS, 2U, 208V:88 mm
    • PM3000 0U Vertical 3-ph 16A 380/400/415V:8 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Rack ATS, 2U, 208V, PM3000 0U Vertical 3-ph 16A 380/400/415V
20 specifications
Designidentical
Product colourBlackBlack
Rack capacityKnown for oneUnknown — not stated by the source0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfacesidentical
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one16x IEC 320 C13 2x IEC 320 C19Unknown — not stated by the source
I/O portsKnown for oneUnknown — not stated by the source- 3 x IEC 60320 C19, - 21 x IEC 60320 C13, - 1 x 10/100/1000 Base-T(X) Ethernet
Featuresidentical
Cable lengthKnown for one2.44 mUnknown — not stated by the source
Power1 differ
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum input current per phaseDiffers30 A16 A
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Certificates1 differ
CertificationDiffersEN 55022 Class A,FCC Part 15 Class A,PSE,TUV-C,TUV-NURTLUL, FCC, cUL, CE, VCCI, C-Tick, CB
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 45 °C10 - 50 °C
Storage temperature (T-T)Differs-25 - 65 °C-40 - 65 °C
Operating relative humidity (H-H)Differs5 - 95%20 - 80%
Storage relative humidity (H-H)5 - 95%5 - 95%
Weight & dimensions3 differ
WidthDiffers432 mm5.6 mm
DepthDiffers236 mm167.6 mm
HeightDiffers88 mm8 mm
WeightKnown for one6.5 kgUnknown — not stated by the source
Weight (imperial)Known for oneUnknown — not stated by the source6.71 kg (14.8 lbs)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.