Product comparison · 2 power distribution units (pdus)

APC PE6U4W power distribution unit (PDU) 6 AC outlet(s) White vs Vertiv Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19

Add a product
  • 17specifications compared
  • 16differ
  • 1identical
  • 21known for one product only

Key differences

  • Mounting
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:Horizontal/Vertical
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:Vertical
  • Product colour
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:White
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:Black
  • AC outlets quantity
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:6 AC outlet(s)
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:24 AC outlet(s)
  • Power plug
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:NEMA 5-15P
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:C20 coupler
  • AC outlet types
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:NEMA 5-15R
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:C13 coupler, C19 coupler
  • LED indicators
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:Yes
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:No
  • Maximum current
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:15 A
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:16 A
  • Operating temperature (T-T)
    • PE6U4W power distribution unit (PDU) 6 AC outlet(s) White:32 - 104 °F
    • Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19:0 - 45 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of PE6U4W, Geist rPDU, basic, 0U, input C20 230V 16A, outputs (20)C13 | (4)C19
38 specifications
Design2 differ
MountingDiffersHorizontal/VerticalVertical
Product colourDiffersWhiteBlack
On/off switchKnown for oneYesUnknown — not stated by the source
PDU typesKnown for oneUnknown — not stated by the sourceBasic
Rack capacityKnown for oneUnknown — not stated by the source0U
Ports & interfaces3 differ
AC outlets quantityDiffers6 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA 5-15PC20 coupler
AC outlet typesDiffersNEMA 5-15RC13 coupler, C19 coupler
USB ports quantityKnown for one4Unknown — not stated by the source
Output connectionsKnown for oneUnknown — not stated by the source20 x C13 & 4 x C19
Features1 differ
LED indicatorsDiffersYesNo
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Power1 differ
Maximum currentDiffers15 A16 A
Surge energy ratingKnown for one1080 JUnknown — not stated by the source
Nominal input voltageKnown for oneUnknown — not stated by the source230 V
AC input frequencyKnown for oneUnknown — not stated by the source50 Hz
Load capacityKnown for oneUnknown — not stated by the source3600 VA
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneUnknown — not stated by the sourceCE, RoHS, CB
Operational conditions1 differ
Operating temperature (T-T)Differs32 - 104 °F0 - 45 °C
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers69 mm1207 mm
DepthDiffers132 mm51 mm
HeightDiffers135 mm51 mm
WeightDiffers690 g3.1 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers770 g3.63 kg
Package widthDiffers120 mm1270 mm
Package depthDiffers171 mm127 mm
Package heightDiffers138 mm77 mm
Logistics dataidentical
Master (outer) case widthKnown for one318 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one410 mmUnknown — not stated by the source
Master (outer) case heightKnown for one190 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one5.48 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons